Siemens 3VA1163-1AA42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0AA0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA42-0AA0
Active

Siemens SENTRON 3VA1163-1AA42-0AA0, switch disconnector in MCCB design, IEC frame 160, 4-pole SD100, In=63 A, without overload or short-circuit protection, busbar connection, front terminal, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-1AA42-0AA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON

Ratings

3VA1163-1AA42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Power loss, max.38 W

Construction & Connection

3VA1163-1AA42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-1AA42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1163-1AA42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-1AA42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width101.6 mm
Depth70 mm

Product details

Switch Disconnector for Load-Break Isolation

The Siemens 3VA1163-1AA42-0AA0 is a SENTRON switch disconnector built in an MCCB form factor — IEC frame 160, 4-pole, rated 63 A continuous — designed for safe load-break isolation without overload or short-circuit protection. It is a pure disconnecting means: no trip unit, no undervoltage release, no auxiliary contacts. That makes it the right choice when you need a visible-break isolator that fits a standard MCCB footprint and handles full rated current across the entire operating temperature range. Rated current holds flat at 63 A from 40 °C through 70 °C — no derating curve to track. That simplifies panel thermal budgeting in warm enclosures or near other heat sources. Insulation voltage is rated 800 V; operating voltage is 690 V AC or 600 V DC, so it covers 480 V and 600 V class systems with headroom. Mechanical service life is 15,000 operating cycles typical. That is adequate for routine isolation in a panel that sees weekly or monthly switching.

Mounting and Connection

Main circuit connection is busbar-compatible via front terminals — the busbar connection type and front terminal arrangement mean it integrates into standard panel busbar systems without adapters. Dimensions: 70 mm deep, 101.6 mm wide, 130 mm tall. That width is a standard 4-pole MCCB footprint; verify busbar pitch matches your existing layout. Front protection is IP40 — suitable for enclosed panel mounting where the front face is behind a door. No auxiliary switch or release fitted, and no communication function. Optional motor drive can be added via the product extension slot if remote operation is needed.

Lifecycle and Sourcing

For compliance documentation: as a Siemens SENTRON product, it carries the usual CE marking for the European market and is designed to relevant IEC standards (IEC 60947-3 for switch-disconnectors). RoHS and REACH declarations are available from Siemens documentation portal using the order code.

Frequently asked questions

What is the closest functional second-source for 3VA1163-1AA42-0AA0?

The 3VA1110-5ED32-0AA0 is a peer in the same SENTRON 3VA1 family but it is a different configuration — it carries overload and short-circuit protection (a true MCCB), whereas the 3VA1163-1AA42-0AA0 is a pure switch disconnector with no protection. They share the same frame size and busbar connection pattern, so panel cutout and busbar pitch are compatible, but the wiring and protection scheme are different. Do not substitute without reviewing the protection requirements of your circuit.

MPN