Skip to main content
Siemens 3VA1163-1AA42-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0AB0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA42-0AB0

Siemens SENTRON 3VA1163-1AA42-0AB0, switch disconnector in MCCB design, IEC frame 160, 4-pole SD100, In = 63 A, without overload or short-circuit protection, with nut keeper kit and 2 auxiliary switches HP.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-1AA42-0AB0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON

Ratings

3VA1163-1AA42-0AB0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Power loss, max.38 W

Construction & Connection

3VA1163-1AA42-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-1AA42-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1163-1AA42-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-1AA42-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width101.6 mm
Depth70 mm

Product details

What this part is and where it lands in the panel

The Siemens SENTRON 3VA1163-1AA42-0AB0 is a 4-pole switch disconnector built in an MCCB-style frame (IEC frame 160) rated at a continuous 63 A. It carries no overload or short-circuit protection — it is a pure disconnect, sized for isolating a load circuit under load or no-load conditions. The 63 A rating holds flat across the full operating temperature range from 40 °C up to 70 °C, so no derating curve to track for warm enclosures. Rated insulation voltage is 800 V, with AC operating voltage to 690 V and DC to 600 V. It ships with a nut keeper kit and two factory-installed auxiliary switches (HP type) for status feedback back to the PLC or safety relay.

What the ratings mean for fit

The 63 A rating is continuous and temperature-independent across the operating range (-25 °C to 70 °C), so it handles a full 63 A load even in a hot panel near the top of the enclosure. The 4-pole design (3 poles + switched neutral) makes it suitable for three-phase systems where the neutral needs isolation. Front terminals accept busbar connection for the main circuit, which keeps wiring tidy in a distribution panel. The IP40 front protection means it is fine in a clean indoor panel but not for washdown environments. Mechanical life is rated at 15,000 operating cycles — adequate for infrequent disconnect duty (maintenance isolation) rather than daily switching. Power loss at rated current is 38 W, which matters for thermal budgeting in a densely packed enclosure.

Panel integration notes

Mounts in a standard MCCB cutout — 70 mm depth, 101.6 mm width, 130 mm height. The front terminals and busbar connection mean the busbars run across the front, not the rear, so plan the busbar routing accordingly. The two auxiliary switches (HP) are pre-installed and wired; they provide status feedback without needing a separate auxiliary contact block. Optional motor drive available for remote operation. No undervoltage release or shunt trip on this variant — if you need those, look at the 3VA1 family with the release option.

Frequently asked questions

What is the current rating and does it derate with temperature?

Rated 63 A continuous, and it holds that rating flat from 40 °C all the way to 70 °C. No derating needed for warm enclosures within that range.

Where can I buy 3VA1163-1AA42-0AB0 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

Does this part include overload or short-circuit protection?

No. It is a switch disconnector only — no overload release, no short-circuit protection. It isolates the load circuit but does not protect it. Overcurrent protection must be provided upstream.

MPN