Siemens 3VA1163-1AA42-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0AC0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA42-0AC0

Siemens SENTRON 3VA1 switch disconnector, IEC frame 160, 4-pole SD100, In=63 A, without overload or short-circuit protection, busbar connection, 2 HQ auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA42-0AC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1163-1AA42-0AC0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Power loss, max.38 W
3VA1163-1AA42-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA42-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1163-1AA42-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA42-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width101.6 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1163-1AA42-0AC0 is a 4-pole switch disconnector in MCCB design, rated 63 A continuous across the full operating temperature range from 40 °C to 70 °C — no derating needed up to the maximum ambient. It is built on the IEC frame 160 platform and carries the SD100 designation, meaning it provides isolation and switching without overload or short-circuit protection. Maximum power loss is 38 W. Two HQ auxiliary changeover contacts are built in. Mechanical service life is 15 000 operating cycles typical.

Front terminals accept busbar connection for the main circuit. An optional motor drive can be added for remote switching.

Frequently asked questions

Where can I buy 3VA1163-1AA42-0AC0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote — availability and current pricing are confirmed at quote time.

Will 3VA1163-1AA42-0AC0 drop into a panel specified around 3VA1110-5ED36-0AC0?

No — the 3VA1110-5ED36-0AC0 is a 3-pole molded case circuit breaker with overcurrent protection, 76.2 mm wide, while this 4-pole switch disconnector is 101.6 mm wide. Different footprint and function; rewiring and panel cutout changes are required.