Skip to main content
Siemens 3VA1163-1AA42-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0AD0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA42-0AD0

Siemens SENTRON 3VA1 IEC frame 160, switch disconnector, 4-pole, In = 63 A, without overload or short-circuit protection, 3 auxiliary switches HQ, busbar connection, front terminal, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA42-0AD0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1163-1AA42-0AD0 — Ratings
ParameterValue
Number of poles4
Power loss, max.38 W
3VA1163-1AA42-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA42-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1163-1AA42-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA42-0AD0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

The Siemens 3VA1163-1AA42-0AD0 is a SENTRON switch disconnector in an MCCB-style housing (IEC frame 160), rated for 63 A continuous current across 4 poles. It provides visible isolation for a circuit — it makes and breaks load current but carries no overload or short-circuit protection. The part is designed for applications where disconnection is needed downstream of a separate protective device, such as a main breaker or fuse.

Rated continuous current Iu is 63 A — sized for a 63 A busbar tap or feeder. Max AC operational voltage is 690 V 50/60 Hz; max DC is 600 V. The 4-pole configuration allows switching of three phases plus neutral in TN or TT systems, or four-phase DC circuits.

Front terminal busbar connection matches the SENTRON busbar system. IP40 on the front.

Auxiliary contacts and options

Comes with 3 auxiliary switches HQ (high-quantity, meaning multiple changeover contacts) — 3 CO contacts total. Motor drive is available as an optional add-on (product extension optional motor drive = Yes). Maximum power loss is 38 W.

Frequently asked questions

What is the difference between 3VA1163-1AA42-0AD0 and 3VA1010-2ED42-0AE0?

The 3VA1010-2ED42-0AE0 is a molded case circuit breaker with line protection (overload and short-circuit release), rated 100 A, while the 3VA1163-1AA42-0AD0 is a switch disconnector with no protection, rated 63 A. Both share the same 70 mm depth, 101.6 mm width, and 130 mm height, so they can occupy the same panel footprint, but the circuit breaker includes a TM210 trip unit and higher breaking capacity, whereas the switch disconnector is purely a disconnect device with 3 auxiliary switches.

MPN
3VA1163-1AA42-0AD0