Skip to main content
Siemens 3VA1163-1AA42-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0AG0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA42-0AG0

Siemens SENTRON 3VA1163-1AA42-0AG0, IEC frame 160 switch disconnector in MCCB design, 4-pole, In = 63 A, without overload or short-circuit protection, busbar connection, front terminals, 1 auxiliary switch HP + 1 trip alarm switch HP, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA42-0AG0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1163-1AA42-0AG0 — Ratings
ParameterValue
Number of poles4
Power loss, max.38 W
3VA1163-1AA42-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA42-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1163-1AA42-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA42-0AG0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

It provides no overload or short-circuit protection — it's a disconnect-only device for isolating a circuit under load. Front terminals accept busbar connection, and the IP40 front protection suits enclosed panel mounting.

The max power loss of 38 W at rated current matters for enclosure thermal calculations: a panel with several such switches needs ventilation or derating above 40 °C ambient.

The IP40 front (protected against tools >1 mm, no water protection) is standard for enclosed switchgear — not for washdown or outdoor use without an additional enclosure. The auxiliary contact pack includes one auxiliary switch (signal open/closed) and one trip alarm switch HP (signals a fault trip from the upstream protection), both rated for 24 V DC control circuits typical in PLC inputs.

Frequently asked questions

Where can I buy 3VA1163-1AA42-0AG0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key specifications of 3VA1163-1AA42-0AG0?

Rated continuous current Iu = 63 A, 4 poles, max AC operational voltage 690 V, max DC operational voltage 600 V, IP40 front protection, busbar connection with front terminals, includes 1 auxiliary switch HP and 1 trip alarm switch HP.

MPN
3VA1163-1AA42-0AG0