Skip to main content
Siemens 3VA1163-1AA42-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0AG0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA42-0AG0

Siemens SENTRON 3VA1163-1AA42-0AG0, IEC frame 160 switch disconnector in MCCB design, 4-pole, In = 63 A, without overload or short-circuit protection, busbar connection, front terminals, 1 auxiliary switch HP + 1 trip alarm switch HP, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-1AA42-0AG0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design

Ratings

3VA1163-1AA42-0AG0 — Ratings
ParameterValue
Number of poles4
Power loss, max.38 W

Construction & Connection

3VA1163-1AA42-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-1AA42-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1163-1AA42-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-1AA42-0AG0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1163-1AA42-0AG0 is a 4-pole switch disconnector in MCCB design, rated at 63 A continuous current (Iu). It provides no overload or short-circuit protection — it's a disconnect-only device for isolating a circuit under load. The 690 V AC (50/60 Hz) or 600 V DC rating covers most industrial panel voltages. Front terminals accept busbar connection, and the IP40 front protection suits enclosed panel mounting.

What the ratings mean for fit

The 63 A rated continuous current (Iu) is the maximum current the switch can carry continuously without exceeding temperature rise limits. For motor circuits, that typically covers a 30–37 kW motor at 400 V AC-3 duty, but this part carries no short-circuit or overload trip curve — the upstream feeder breaker or fuse provides that protection. The 4-pole design switches all three phases plus neutral, required for TN-S or TT systems where the neutral must be isolated. The max power loss of 38 W at rated current matters for enclosure thermal calculations: a panel with several such switches needs ventilation or derating above 40 °C ambient.

Panel integration notes

Dimensions are 130 mm height × 101.6 mm width × 70 mm depth. The front-terminal busbar connection means it mounts on a DIN rail or panel base with busbar fingers feeding the line side. The IP40 front (protected against tools >1 mm, no water protection) is standard for enclosed switchgear — not for washdown or outdoor use without an additional enclosure. The auxiliary contact pack includes one auxiliary switch (signal open/closed) and one trip alarm switch HP (signals a fault trip from the upstream protection), both rated for 24 V DC control circuits typical in PLC inputs.

Frequently asked questions

Where can I buy 3VA1163-1AA42-0AG0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key specifications of 3VA1163-1AA42-0AG0?

Rated continuous current Iu = 63 A, 4 poles, max AC operational voltage 690 V, max DC operational voltage 600 V, IP40 front protection, busbar connection with front terminals, includes 1 auxiliary switch HP and 1 trip alarm switch HP.

MPN
3VA1163-1AA42-0AG0