Skip to main content
Siemens 3VA1163-1AA42-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0BA0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA42-0BA0

Siemens SENTRON 3VA1 IEC frame 160, 4-pole switch disconnector SD100, 63 A, without overload or short-circuit protection, busbar connection, undervoltage release 24 V DC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA42-0BA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1163-1AA42-0BA0 — Ratings
ParameterValue
Number of poles4
Power loss, max.38 W
3VA1163-1AA42-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA42-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1163-1AA42-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA42-0BA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

The Siemens 3VA1163-1AA42-0BA0 is a SENTRON 3VA1 switch disconnector in a 4-pole configuration, rated for 63 A continuous current (Iu) on a 160 A frame. It is designed for isolation and switching of circuits where overload or short-circuit protection is handled upstream or by a separate device — the listing explicitly notes it ships without overload protection and without short-circuit protection. Rated insulation voltage (Ui) is 800 V, with a maximum operational voltage of 690 V AC 50/60 Hz and 600 V DC.

The 63 A rated continuous current (Iu) sets the maximum load this disconnector can carry continuously without exceeding its thermal limits. For a 4-pole device on a 160 A frame, this means the internal current path and busbar connections are physically sized for higher current, but the part is factory-limited to 63 A — it is not field-upgradable to a higher rating. The undervoltage release (UVR) is factory-fitted and designed for 24 V DC. The UVR does not include a leading contact; verify coil polarity and suppression for the DC circuit. This is the expected life under no-load or low-load switching; frequent loaded switching will reduce service life.

Panel integration and connection

The main current circuit uses busbar connection with front terminal arrangement. This means the disconnector is designed to plug onto a busbar system (typically Siemens 3VA busbar adapters) rather than accepting lug or cable terminations directly. The 101.6 mm width (4-inch form factor) and 70 mm depth fit the standard 3VA1 panel footprint; mounting holes and busbar slots align with the SENTRON 3VA family. An optional motor drive can be added via the product extension slot. No auxiliary contacts are included (0 CO contacts, auxiliary contact version 'Without'). If status feedback is needed, a separate auxiliary switch module must be ordered and fitted. The trip indicator is also absent — visual confirmation of the open/closed state comes from the handle position only.

Frequently asked questions

What is the difference between this switch disconnector and a molded case circuit breaker like the 3VA1112-5EF32-0CA0?

The 3VA1163-1AA42-0BA0 is a switch disconnector only — it provides isolation and switching but no overload or short-circuit protection. The 3VA1112-5EF32-0CA0 is a full molded case circuit breaker (MCCB) with a TM240 thermal-magnetic trip unit rated at 125 A, offering LI protection. The disconnector is 4-pole and 101.6 mm wide; the MCCB is 3-pole and 76.2 mm wide, so they do not share the same panel cutout or busbar footprint. The disconnector cannot be substituted for an MCCB where overcurrent protection is required.

Where can I buy the 3VA1163-1AA42-0BA0?

This part is sourced and quoted to order against an RFQ through independent industrial automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Siemens provide for this switch disconnector?

Siemens typically provides a Declaration of Conformity covering the Low Voltage Directive (2014/35/EU) and applicable harmonized standards. The SENTRON 3VA series carries CE marking and is designed to meet IEC 60947-3 for switch-disconnectors. RoHS and REACH compliance declarations are available from Siemens support. Specific certification (UL/CSA) should be verified against the exact order code variant.

MPN
3VA1163-1AA42-0BA0