Skip to main content
Siemens 3VA1163-1AA42-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0BC0 SENTRON Switch Disconnector, 63 A

MPN3VA1163-1AA42-0BC0

Siemens SENTRON 3VA1163-1AA42-0BC0, switch disconnector in MCCB design, 4-pole, 63 A rated continuous current, 690 V AC / 600 V DC, with undervoltage release 24 V DC and 2 auxiliary switches HQ, busbar connection front terminal.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-1AA42-0BC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design

Ratings

3VA1163-1AA42-0BC0 — Ratings
ParameterValue
Number of poles4
Power loss, max.38 W

Construction & Connection

3VA1163-1AA42-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-1AA42-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1163-1AA42-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-1AA42-0BC0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

Switch Disconnector for Isolation and Safety Switching

The Siemens SENTRON 3VA1163-1AA42-0BC0 is a 4-pole switch disconnector in MCCB design, rated at 63 A continuous current (Iu) with a maximum AC operational voltage of 690 V and DC voltage of 600 V. It provides no overload or short-circuit protection — its role is safe isolation and disconnection under load, not fault clearing. The built-in undervoltage release (UVR) at 24 V DC automatically opens the switch when control voltage drops, a standard requirement for emergency-stop and safety circuits.

What the Ratings Mean for Your Panel

The 63 A rated continuous current (Iu) is the maximum current the switch can carry continuously without exceeding its thermal limits — sized for a 63 A feeder or motor branch circuit. The 690 V AC / 600 V DC rated operational voltage covers standard three-phase 400 V and 480 V systems with headroom, and the DC rating allows use in battery or UPS circuits. The 2 kA limited short-time withstand (1 s and 0.5 s) means it can survive a fault current of that magnitude while the upstream protective device clears — it is not a circuit breaker and must be coordinated with a fuse or MCCB upstream.

Integration and Mounting

The switch disconnector uses busbar connection on the front terminals for the main circuit — designed for panel-mount with busbar links, not cable lugs. Dimensions are 70 mm deep, 101.6 mm wide, 130 mm high, fitting the standard 3VA1 frame 160 footprint. IP40 front protection means it is suitable for enclosed panel installation, not open washdown areas. The 2 auxiliary switches (HQ type) provide status feedback to a PLC or safety relay.

Frequently asked questions

Where can I buy 3VA1163-1AA42-0BC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation is available for this part?

As a Siemens SENTRON product, it carries CE marking and is designed to IEC/EN 60947-3 standards for switch-disconnectors. RoHS and REACH declarations are available from Siemens on request.

MPN
3VA1163-1AA42-0BC0