Siemens 3VA1163-1AA42-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0CC0 SENTRON 4-Pole Switch Disconnecto

MPN3VA1163-1AA42-0CC0

Siemens SENTRON 3VA1163-1AA42-0CC0, 4-pole switch disconnector in MCCB design, 63 A rated continuous current, 690 V AC / 600 V DC, IP40 front, with undervoltage release and 2 auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-1AA42-0CC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design

Ratings

3VA1163-1AA42-0CC0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Power loss, max.38 W

Construction & Connection

3VA1163-1AA42-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-1AA42-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1163-1AA42-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-1AA42-0CC0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

The Siemens 3VA1163-1AA42-0CC0 is a SENTRON 4-pole switch disconnector built in MCCB design, rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed as the panel warms up. It handles 690 V AC (50/60 Hz) or 600 V DC, making it a straight fit for 400 V three-phase distribution and DC bus isolation in the same enclosure.

What the ratings mean for your panel

The 63 A rating is flat from 40 °C to 70 °C — no thermal derating curve to calculate. That simplifies BOM sizing for a warm cabinet or a line-side disconnect near a motor drive. Rated insulation voltage Ui of 800 V gives headroom above the 690 V AC operational maximum, so the switch suits 690 V systems without creeping along the insulation boundary. The front terminals accept busbar connection, which means it drops into a panel busbar system without extra adapters. IP40 on the front keeps finger probes out; the rest of the enclosure is the panel's own IP rating. Two auxiliary switches (HQ type) with 2 CO contacts are built in — enough to signal the switch position back to a PLC or safety circuit without an add-on block.

Undervoltage release and lifecycle

This unit ships with an undervoltage release (UVR) fitted. That means the switch trips automatically when control voltage drops below a threshold — standard for safety isolation on conveyor zones or machine sections where loss of control power should open the disconnect. Latching endurance is rated at 15 000 cycles, which covers years of daily switching in a material-handling line. The optional motor drive allows remote operation if the panel is hard to reach.

Sourcing and fit

Dimensions: 70 mm deep, 101.6 mm wide, 130 mm high. The width matches standard 4-pole MCCB footprints, so it should fit existing panel cutouts or DIN-rail layouts without re-drilling.

Frequently asked questions

What is the closest functional second-source for 3VA1163-1AA42-0CC0?

The peer MPNs 5SQ2670-2YA63, 5SQ2670-2YA16, and 5SQ2670-0KA15 are listed as alternatives, but the 3VA1163-1AA42-0CC0 includes an undervoltage release and 2 auxiliary switches as standard — verify that the peer carries the same auxiliary and release configuration before substituting.

MPN