Skip to main content
Siemens 3VA1163-1AA42-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0CC0 SENTRON 4-Pole Switch Disconnecto

MPN3VA1163-1AA42-0CC0

Siemens SENTRON 3VA1163-1AA42-0CC0, 4-pole switch disconnector in MCCB design, 63 A rated continuous current, 690 V AC / 600 V DC, IP40 front, with undervoltage release and 2 auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA42-0CC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1163-1AA42-0CC0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Power loss, max.38 W
3VA1163-1AA42-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA42-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1163-1AA42-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA42-0CC0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

The Siemens 3VA1163-1AA42-0CC0 is a SENTRON 4-pole switch disconnector built in MCCB design, rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed as the panel warms up. It handles 690 V AC (50/60 Hz) or 600 V DC, making it a straight fit for 400 V three-phase distribution and DC bus isolation in the same enclosure.

That simplifies BOM sizing for a warm cabinet or a line-side disconnect near a motor drive. The front terminals accept busbar connection, which means it drops into a panel busbar system without extra adapters. IP40 on the front keeps finger probes out; the rest of the enclosure is the panel's own IP rating.

Undervoltage release and lifecycle

The optional motor drive allows remote operation if the panel is hard to reach.

The width matches standard 4-pole MCCB footprints, so it should fit existing panel cutouts or DIN-rail layouts without re-drilling.

Frequently asked questions

What is the closest functional second-source for 3VA1163-1AA42-0CC0?

The peer MPNs 5SQ2670-2YA63, 5SQ2670-2YA16, and 5SQ2670-0KA15 are listed as alternatives, but the 3VA1163-1AA42-0CC0 includes an undervoltage release and 2 auxiliary switches as standard — verify that the peer carries the same auxiliary and release configuration before substituting.

MPN
3VA1163-1AA42-0CC0