Skip to main content
Siemens 3VA1163-1AA42-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-1AA42-0DC0 SENTRON Switch Disconnector, 63A,

MPN3VA1163-1AA42-0DC0

Siemens SENTRON 3VA1163-1AA42-0DC0, switch disconnector in MCCB design, 4-pole, 63 A, undervoltage release 208-230 V AC 50/60 Hz, 2 HQ auxiliary switches, busbar connection front terminal.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-1AA42-0DC0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1163-1AA42-0DC0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Power loss, max.38 W
3VA1163-1AA42-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-1AA42-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1163-1AA42-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-1AA42-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width101.6 mm
Depth70 mm

Product details

Switch disconnector for isolation and safety disconnection

The Siemens SENTRON 3VA1163-1AA42-0DC0 is a 4-pole switch disconnector in MCCB design, rated 63 A continuous across the full operating range from 40 °C to 70 °C — no derating needed up to the 70 °C max. It provides load-break isolation for a 690 V AC or 600 V DC circuit, with an undervoltage release (UVR) coil rated 208-230 V AC 50/60 Hz that trips the switch on loss of control voltage. The UVR is wired in series with an emergency-stop or guard-door contact — when that circuit opens, the disconnector opens instantly, isolating downstream loads. The HQ aux switches are rated for high mechanical endurance and share the same 15 000-cycle mechanical life as the main switch. No overload or short-circuit protection is built in; this part is a pure disconnector, not a circuit breaker.

Flat thermal curve simplifies panel sizing

That means the 63 A nameplate holds even in a hot enclosure near a drive or transformer. Busbar connection on the front terminals keeps wiring clean and reduces cable congestion in the panel.

Frequently asked questions

How do I get current pricing and availability for 3VA1163-1AA42-0DC0?

Submit an RFQ through this listing. Pricing and lead time are confirmed at quote time against current market conditions.

Will 3VA1163-1AA42-0DC0 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

No — the 3VA1163-1AA42-0DC0 is a 4-pole switch disconnector (101.6 mm wide) while the 3VA1110-5ED36-0AC0 is a 3-pole MCCB (76.2 mm wide). The width difference and the UVR wiring requirement mean a panel rework is needed.

MPN
3VA1163-1AA42-0DC0