Skip to main content
Siemens 3VA1163-3ED36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-3ED36-0AA0 SENTRON MCCB, 63 A, 3-Pole, 75.6

MPN3VA1163-3ED36-0AA0
Active

Siemens SENTRON 3VA1163-3ED36-0AA0, molded case circuit breaker, 3-pole, 63 A, TM210 thermal-magnetic release, 75.6 kA breaking capacity at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-3ED36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1163-3ED36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.17.3 W
3VA1163-3ED36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1163-3ED36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-3ED36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1163-3ED36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-3ED36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What you're getting with the 3VA1163-3ED36-0AA0

It's built for line protection — think main feeder or large subfeed in a distribution panel, not motor branch circuit duty where you'd want a motor-protective breaker. Breaking capacity climbs to 75.6 kA at 240 V AC, drops to 52.5 kA at 415 V, and holds at 11.9 kA at 690 V. That's a lot of fault current for a 63 A frame — it'll clear a hard short on a 400 V industrial feeder without the upstream breaker having to flinch. Insulation voltage is rated 800 V, so it's comfortable in 480/277 V or 400/230 V panels with headroom.

At 40 °C it carries the full 63 A. Derating starts at 55 °C (62 A) and drops to 58 A at 70 °C. That's a 3-inch wide body — standard for a 63 A frame in the SENTRON 3VA line. It'll bolt into a panel that was laid out for a 3VA1110 or 3VA1112 without drilling new holes, but check the lug kit orientation; the line and load connections are the same pattern across the 3VA family.

MPN
3VA1163-3ED36-0AA0