Skip to main content
Siemens 3VA1163-3EF32-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-3EF32-0AA0-ZD00 Circuit Breaker, 63A, 25kA @

MPN3VA1163-3EF32-0AA0-ZD00

Siemens 3VA1 IEC frame 160, 3-pole circuit breaker, 63 A, breaking capacity class N Icu=25 kA @ 415 V, TM240 thermal-magnetic trip, ATAM, overload Ir=44…63 A, short-circuit Ii=5…10 x In, with nut keeper kit for DC Power OEM in China.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1163-3EF32-0AA0-ZD00 is a 3-pole IEC frame 160 circuit breaker rated 63 A, with a breaking capacity class N of Icu=25 kA at 415 V. It uses a TM240 thermal-magnetic trip unit — the TM240 designation means the thermal element is sized for a 63 A continuous current, with overload protection adjustable from Ir=44 A to 63 A. Short-circuit magnetic pickup is fixed at Ii=5 to 10 times In, so the instantaneous trip point sits between 315 A and 630 A. This variant includes a nut keeper kit and is specified for DC Power OEM applications in China.

The adjustable overload Ir=44…63 A lets you dial in the exact motor FLA or feeder load without swapping the trip unit. The Ii=5…10 x In magnetic range means nuisance tripping on moderate inrush (like a transformer or capacitor bank) is less likely than a fixed-high setting breaker.

Deployment context

Mounts on a DIN rail in a standard 3-pole width — fits a 160 A frame footprint, so panel fill factor and gland plate planning should account for the larger frame size versus a 63 A breaker in a 125 A frame. The nut keeper kit is for DC Power OEM builds where vibration or transport can loosen terminal connections.

Frequently asked questions

How do I get current pricing and availability for 3VA1163-3EF32-0AA0-ZD00?

Submit an RFQ — the part is sourced and quoted to order. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is the breaking capacity of this circuit breaker?

The breaking capacity is Icu=25 kA at 415 V, breaking capacity class N per IEC standards.

What is the adjustable overload range on this breaker?

The TM240 thermal-magnetic trip unit allows overload protection adjustment from Ir=44 A to 63 A.

MPN
3VA1163-3EF32-0AA0-ZD00