Skip to main content
Siemens 3VA1163-3EF32-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-3EF32-0KH0 SENTRON MCCB, 63 A, 75.6 kA at 24

MPN3VA1163-3EF32-0KH0

Siemens SENTRON 3VA1163-3EF32-0KH0, molded case circuit breaker, 3-pole, 63 A rated continuous current Iu, 75.6 kA breaking capacity at 240 V, line protection, with shunt trip (STL) and 2 auxiliary + 1 trip alarm switch HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-3EF32-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1163-3EF32-0KH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V10.5 kA
3VA1163-3EF32-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1163-3EF32-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-3EF32-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1163-3EF32-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-3EF32-0KH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1163-3EF32-0KH0 is a 3-pole molded case circuit breaker rated for 63 A continuous current at 40 °C, with a thermal-magnetic release (TM240) tuned for line protection.

Breaking capacity across voltages — selectivity planning

Breaking capacity drops as voltage rises: 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V. If your fault-current study shows a higher prospective short-circuit at your system voltage, this breaker may not coordinate — verify the point-of-common-coupling level before committing the BOM line.

Thermal derating — real-world current handling

Full 63 A holds through 50 °C ambient. Above that, it derates: 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, and 56.7 A at 70 °C.

The lifecycle stage is current — this is an active, in-production part.

Mounting and enclosure fit

The 76.2 mm width (roughly 3 inches) matches standard MCCB mounting footprints; verify the backplate cutout against your existing DIN-rail or panel-mount pattern.

Frequently asked questions

Where can I buy 3VA1163-3EF32-0KH0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is the breaking capacity of 3VA1163-3EF32-0KH0 at 240 V?

75.6 kA at 240 V, with lower ratings at higher voltages: 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V.

What auxiliary contacts come with this MCCB?

It includes 2 auxiliary switches plus 1 trip alarm switch HQ, plus a shunt trip (STL) release.

What compliance documentation does Siemens provide for this part?

As a Siemens SENTRON product, it carries the standard certifications for molded case circuit breakers including IEC/EN 60947-2 compliance. Specific documentation (RoHS, REACH, UL) is available on request with the RFQ.

MPN
3VA1163-3EF32-0KH0