Skip to main content
Siemens 3VA1163-4ED12-0AA0 — Molded Case Circuit Breakers (MCCB)

3VA1163-4ED12-0AA0 SENTRON MCCB, 1-pole 63A, 75.6kA at 240V

MPN3VA1163-4ED12-0AA0
Active

Siemens SENTRON 3VA1163-4ED12-0AA0, 1-pole molded case circuit breaker, 63 A rated, TM210 release, 75.6 kA at 240 V, 9 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-4ED12-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1163-4ED12-0AA0 — Ratings
ParameterValue
Number of poles1
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classS
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V9 kA
Power loss, max.5.77 W
3VA1163-4ED12-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1163-4ED12-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-4ED12-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1163-4ED12-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-4ED12-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width25.4 mm
Depth70 mm
Height (in)5.12 in
Width (in)1 in
Depth (in)2.76 in

Product details

MCCB for line protection — 63 A, 1-pole, TM210 release

This single-pole MCCB occupies a 25.4 mm (1 in) width on the DIN rail, with a depth of 70 mm and height of 130 mm — a compact footprint that fits standard distribution panels. Front IP40 protection handles typical enclosure environments.

The interrupting capacity tells you where this breaker can sit in a fault-current study. At 240 V AC, it interrupts 75.6 kA — that places it upstream in high-fault locations like a main distribution board. The 1-pole DC rating is 125 V, so it also works for DC branch circuits within that voltage ceiling. Thermal derating is documented across the operating range: 63 A from 45 °C up to 50 °C, then stepping down to 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C.

Lifecycle and sourcing — active production, quoted to order

Panel integration — DIN-rail mounting, single-pole footprint

Mounts on standard DIN rail. The 25.4 mm width means one pole per 1 inch of rail space — a 3-pole installation takes 76.2 mm (3 in). Depth of 70 mm leaves clearance for wiring and busbar connections behind the breaker. Front IP40 is sufficient for enclosed panel use; no washdown rating needed here.

Frequently asked questions

What is the breaking capacity at 240 V and 415 V?

At 240 V AC the interrupting capacity is 75.6 kA; at 415 V AC it is 9 kA. The DC rating is 125 V.

What is the thermal derating from 45 °C to 70 °C?

Rated 63 A from 45 °C to 50 °C, then 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C.

Will 3VA1163-4ED12-0AA0 drop into a panel specified around 3VA1010-2ED32-0JA0?

Both are 1-pole SENTRON MCCBs sharing the same 25.4 mm width and 70 mm depth, so mechanical fit on the DIN rail is identical. However, the 3VA1010-2ED32-0JA0 is a different current rating and release — verify your load and protection coordination before substituting.

Where can I buy 3VA1163-4ED12-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA1163-4ED12-0AA0