Skip to main content
Siemens 3VA1163-4EF32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-4EF32-0BA0 SENTRON MCCB, 63A, 3-Pole, 121kA

MPN3VA1163-4EF32-0BA0

Siemens SENTRON 3VA1163-4EF32-0BA0, molded case circuit breaker, 3-pole, 63 A, 121 kA at 240 V, undervoltage release, line protection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-4EF32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11634EF320AA0

Ratings

3VA1163-4EF32-0BA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.8 W

Protection & Trip Unit

3VA1163-4EF32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1163-4EF32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-4EF32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1163-4EF32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-4EF32-0BA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1163-4EF32-0BA0 is a 3-pole molded case circuit breaker (MCCB) rated 63 A continuous at 40 °C, with a maximum breaking capacity of 121 kA at 240 V AC. It is designed for line protection and includes an integrated undervoltage release (UVR). The 63 A rating holds steady through 50 °C, then derates linearly to 58 A at 70 °C — useful for panels running warm near other heat sources. The 121 kA interrupting rating at 240 V covers high-fault utility feeds; at 415 V it still clears 75.6 kA, and at 690 V it manages 11.9 kA.

The 76.2 mm width (3 in) and 70 mm depth (2.76 in) fit a standard MCCB slot on a DIN rail or panel-mount base. Height is 130 mm (5.12 in). The undervoltage release (UVR) is factory-fitted — verify coil voltage against the control circuit before wiring; the release trips the breaker on loss of control power, which is typical for emergency-stop chains or undervoltage protection schemes.

Compared to the 3VA1110-5EF32-0LA0 (a 100 A frame with electronic trip), this 3VA1163-4EF32-0BA0 uses a TM240 thermal-magnetic overcurrent release and tops out at 63 A. The 3VA1110-5EF32-0LA0 offers higher ampacity and adjustable trip settings but lacks the factory UVR this unit carries. Panel cutout dimensions are similar across the 3VA1 frame family, so a swap between the two requires checking the lug kit and trip curve, not the mounting footprint.

Insulation voltage is rated 800 V, and maximum power loss at rated load is 19.8 W. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. No communication function or ground-fault monitoring is built in — this is a straightforward thermal-magnetic breaker with undervoltage release, suited for feeder or branch protection where remote monitoring is not required.

MPN
3VA1163-4EF32-0BA0