Skip to main content
Siemens 3VA1163-4EF36-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-4EF36-0AC0 SENTRON MCCB, 63 A, 121 kA at 240

MPN3VA1163-4EF36-0AC0

Siemens SENTRON 3VA1 molded case circuit breaker, 3VA1163-4EF36-0AC0, 63 A, 3-pole, TM240 thermal-magnetic release, 121 kA interrupting at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-4EF36-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11634EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1163-4EF36-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.17.3 W
3VA1163-4EF36-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1163-4EF36-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-4EF36-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1163-4EF36-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-4EF36-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

63 A MCCB with 121 kA interrupting capacity

The Siemens 3VA1163-4EF36-0AC0 is a SENTRON 3VA1 molded case circuit breaker rated for 63 A continuous at 40 °C through 50 °C, with a slight thermal derating to 58 A at 70 °C. Its TM240 thermal-magnetic release provides fixed overload and short-circuit protection for line-feeder applications. The 121 kA interrupting rating at 240 V AC gives substantial fault-clearing headroom in high-available-fault-current panels, dropping to 75.6 kA at 415 V and 52.5 kA at 440 V — still well above typical distribution transformer fault levels.

At 70 mm deep, 76.2 mm wide, and 130 mm tall, the 3VA1 frame fits standard MCCB panel cutouts and DIN-rail adapters. The 3-pole footprint matches the Siemens 3VA family mounting pattern, so a panel laid out for a 3VA1110 or 3VA1112 accepts this 63 A unit without rewiring the bus bars — only the lug kit and phase conductors need to be sized for the higher continuous current.

Frequently asked questions

What are the key interrupting ratings for 3VA1163-4EF36-0AC0?

The MCCB is rated 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V.

What is the continuous current rating and thermal derating for this breaker?

Rated 63 A continuous from 40 °C to 50 °C, derating to 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C.

What is the depth of 3VA1163-4EF36-0AC0?

The depth is 70 mm (2.76 in).

Where can I buy 3VA1163-4EF36-0AC0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA1163-4EF36-0AC0