Skip to main content
Siemens 3VA1163-4GF46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-4GF46-0AA0 SENTRON MCCB, 63 A, 4-Pole, 121 k

MPN3VA1163-4GF46-0AA0
Active

Siemens SENTRON 3VA1163-4GF46-0AA0, 4-pole molded case circuit breaker, 63 A continuous rating, TM240 thermal-magnetic release, 121 kA interrupting at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-4GF46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1163-4GF46-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.17.3 W
3VA1163-4GF46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1163-4GF46-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-4GF46-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1163-4GF46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-4GF46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Panel fit and interrupting capacity

The 3VA1163-4GF46-0AA0: Interrupting capacity is the headline here: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and still 11.9 kA at 690 V. Dimensions: 101.6 mm wide (4 inches), 130 mm tall, 70 mm deep. That width is a standard 4-pole MCCB footprint — fits existing SENTRON mounting bases and busbar adapters without panel rework.

Derating and thermal management

Above that, the curve drops: 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C. That 5 A total loss from 50 °C to 70 °C is mild — the TM240 release is thermally efficient, so you don't lose a full frame size in a hot enclosure. Maximum power dissipation is 17.3 W at rated load; plan ventilation if stacking breakers in a sealed cabinet. The storage floor matters if this sits in an unheated warehouse over winter — no issue down to -40 °C.

No communication function onboard — this is a standalone thermal-magnetic breaker, not a power metering or communication variant. If you need remote trip indication, plan for an auxiliary switch add-on (the product extension for motor drive is available, meaning the mechanical accessories slot is populated).

Frequently asked questions

Where can I buy 3VA1163-4GF46-0AA0 and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — submit an RFQ for your quantity and target delivery window.

What is 3VA1163-4GF46-0AA0's interrupting capacity at 415 V?

75.6 kA at 415 V. That's well above typical industrial panel fault levels (usually 25–50 kA), so it provides headroom for high-capacity transformer feeds.

What compliance documentation does this breaker carry?

As a Siemens SENTRON MCCB, it carries IEC and UL certifications typical for the 3VA series. Specific documentation (declaration of conformity, UL file number) is available on request with the RFQ.

Will 3VA1163-4GF46-0AA0 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

Not directly — the 3VA1110-5ED36-0AC0 is a different frame size and pole count. The 3VA1163-4GF46-0AA0 is a 4-pole 63 A breaker; the 3VA1110 is a 3-pole 100 A unit. Mounting base, busbar pitch, and lug sizes differ. Stick with the exact order code for a drop-in replacement.

MPN