Skip to main content
Siemens 3VA1163-5ED32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-5ED32-0AA0 SENTRON MCCB, 63 A, 3-Pole, TM210

MPN3VA1163-5ED32-0AA0
Active

Siemens SENTRON 3VA series, molded case circuit breaker, 3VA1163-5ED32-0AA0, 3-pole, 63 A, TM210 thermal-magnetic release, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1163-5ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1163-5ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.17.3 W
3VA1163-5ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1163-5ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-5ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1163-5ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-5ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens 3VA1163-5ED32-0AA0 — SENTRON MCCB, 63 A, 3-Pole, TM210

The Siemens 3VA1163-5ED32-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection, rated 63 A continuous at 40 °C with a 3-pole configuration and a TM210 thermal-magnetic overcurrent release. Its breaking capacity reaches 187 kA at 240 V AC and 121 kA at 415 V, tapering to 17 kA at 500 V and 690 V — the SCCR curve a panel designer needs for selectivity coordination downstream of a transformer or generator.

63 A continuous through the temperature range

The breaker holds its full 63 A rating from 40 °C up through 50 °C, then derates gradually: 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C.

TM210 release and line-protection design

The TM210 designation means a thermal-magnetic trip unit with a fixed thermal element and a magnetic pickup set at 10x In (630 A).

At 130 mm high, 76.2 mm wide, and 70 mm deep, the 3VA1163-5ED32-0AA0 occupies a 3-pole MCCB footprint that drops into a standard SENTRON 3VA mounting base or panel-mount cutout. No DIN-rail adapter — this is a bolted-frame breaker for distribution panels and switchgear.

Frequently asked questions

Where can I buy 3VA1163-5ED32-0AA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through our independent distribution channel. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response.

What is the breaking capacity of 3VA1163-5ED32-0AA0 at 240 V?

187 kA at 240 V AC, dropping to 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 500 V and 690 V.

MPN
3VA1163-5ED32-0AA0