Specifications

Identification

3VA1163-5ED32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11635ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1163-5ED32-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.19.8 W

Protection & Trip Unit

3VA1163-5ED32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1163-5ED32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-5ED32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1163-5ED32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-5ED32-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB is and where it fits

The Siemens SENTRON 3VA1163-5ED32-0BC0 is a 3-pole molded case circuit breaker rated 63 A at 40 °C, designed for line protection in distribution panels. It carries a rated insulation voltage of 800 V and delivers a breaking capacity of 187 kA at 240 V AC — enough to handle high-fault utility feeds or transformer secondaries without cascading upstream.

Breaking capacity across the voltage range

The interrupting rating drops as voltage rises: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V. That 17 kA floor at 690 V matters for 600 V class industrial systems — it still clears a substantial fault without needing a current-limiting upstream device.

Thermal derating and power loss

Current rating holds flat at 63 A from 40 °C through 50 °C, then derates to 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C. Maximum power loss is 19.8 W — useful to know for enclosure heat calculations when the panel is tightly packed.

Built-in auxiliary and release options

This variant ships with 2 auxiliary switches (HQ design) and an undervoltage release (UVR) factory-installed. The UVR trips the breaker when control voltage drops, which is standard for emergency-stop circuits or undervoltage protection on motor feeds. No ground-fault monitoring or communication module on this order code — it's a straight line-protection breaker.

Dimensions and panel fit

At 130 mm high, 76.2 mm wide, and 70 mm deep, this 3-pole breaker fits the standard SENTRON 3VA mounting footprint. The 70 mm depth is shallow enough for most 200 mm deep enclosures without crowding the door or busbar connections.

Frequently asked questions

What is the breaking capacity of this MCCB at 240 V?

187 kA at 240 V AC, dropping to 121 kA at 415 V and 75.6 kA at 440 V.

Does this breaker include an undervoltage release?

Yes, the 3VA1163-5ED32-0BC0 has a factory-installed undervoltage release (UVR) and 2 auxiliary switches HQ.

What is the closest functional alternative to 3VA1163-5ED32-0BC0?

The 3VA1110-5ED36-0AC0 is a similar SENTRON MCCB but with a different current rating and accessories — verify the trip unit and aux config against your BOM before substituting.

Where can I buy 3VA1163-5ED32-0BC0 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
3VA1163-5ED32-0BC0