Specifications

3VA1163-5ED32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11635ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1163-5ED32-0DC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.19.8 W
3VA1163-5ED32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1163-5ED32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-5ED32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1163-5ED32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-5ED32-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1163-5ED32-0DC0 is a 3-pole molded case circuit breaker rated for line protection, carrying 63 A continuously at 40 °C and derating to 58 A at 70 °C — a thermal curve that keeps the machine running even in a hot panel without nuisance tripping.

At 76.2 mm wide, 130 mm tall, and 70 mm deep, this MCCB fits standard Siemens 3VA panel cutouts and bus-bar kits — no re-drilling the backplate if you're swapping from an older 3VA1 frame. The 70 mm depth leaves clearance for a standard enclosure with the door closed, even with the UVR coil and auxiliary wiring in place.

Frequently asked questions

What auxiliary switches come with this breaker?

It includes two HQ auxiliary switches, providing status feedback for open/closed and tripped positions without needing external limit switches.