Skip to main content
Siemens 3VA1163-5EF32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-5EF32-0DH0 SENTRON MCCB, 63 A, 3-Pole, 187 k

MPN3VA1163-5EF32-0DH0

Siemens SENTRON 3VA1, molded case circuit breaker, 3-pole, 63 A, 187 kA at 240 V AC, line protection, with undervoltage release and 2 aux + 1 trip alarm switch.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-5EF32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11635EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1163-5EF32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.19.8 W

Protection & Trip Unit

3VA1163-5EF32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1163-5EF32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-5EF32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1163-5EF32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-5EF32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What the ratings mean for fit

The 3VA1163-5EF32-0DH0 is a SENTRON 3VA1 molded case circuit breaker rated 63 A continuous at 40 °C through 50 °C, with a slight thermal derating to 58 A at 70 °C — so it holds full rating in most ventilated enclosures but needs a bump-up if the panel ambient hits 70 °C. The interrupting capacity is 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 440 V, which covers high-fault industrial mains and most transformer-secondaries without cascading upstream. Rated insulation voltage is 800 V, so it's comfortable on 480/277 V and 600 V systems. The 3-pole design with an undervoltage release (UVR) means it drops the load on loss of control voltage — typical for safety circuits or coordinated shutdown sequences. The auxiliary switch configuration — 2 auxiliary switches plus 1 trip alarm switch HQ — gives remote status feedback for both the breaker position and fault trip, which saves adding external relays for a PLC or SCADA input. The UVR is factory-installed, so no field retrofit required. Power loss is 19.8 W maximum, which matters for thermal management inside a sealed enclosure.

Panel integration

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a 3-pole MCCB footprint that fits standard Siemens SENTRON mounting plates and busbar systems. The depth is shallow enough for 200 mm deep enclosures with clearance for rear-connected busbars. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C.

Frequently asked questions

Where can I buy 3VA1163-5EF32-0DH0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the interrupting capacity at 240 V and 480 V?

At 240 V the SCCR is 187 kA; at 415 V it is 121 kA; at 440 V it is 75.6 kA; at 500 V and 690 V it is 17 kA.

Does this breaker include an undervoltage release?

Yes, it is equipped with an undervoltage release (UVR) as the auxiliary release, factory-installed.

What auxiliary switches are fitted on 3VA1163-5EF32-0DH0?

It comes with 2 auxiliary switches plus 1 trip alarm switch HQ, giving remote indication of breaker position and fault trip.

MPN