Skip to main content
Siemens 3VA1163-5EF32-0JH0 — Molded Case Circuit Breakers (MCCB)

3VA1163-5EF32-0JH0 SENTRON MCCB, 63 A, 3-pole, line protecti

MPN3VA1163-5EF32-0JH0

Siemens SENTRON 3VA1163-5EF32-0JH0, molded case circuit breaker, 3-pole, line protection, 63 A at 40 °C, 187 kA at 240 V, with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-5EF32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11635EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1163-5EF32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.17.3 W

Protection & Trip Unit

3VA1163-5EF32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1163-5EF32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-5EF32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1163-5EF32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-5EF32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for line protection — 63 A, 3-pole, with shunt trip

The Siemens SENTRON 3VA1163-5EF32-0JH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, delivering 63 A continuous at 40 °C ambient and holding that rating through 50 °C — only dropping to 62 A at 55 °C and 60 A at 65 °C, so the thermal margin is generous for most panel environments. Interrupting capacity is 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V — that covers high-fault utility feeds and transformer secondaries where SCCR headroom matters. It ships with a shunt trip release (STL) and an auxiliary switch block: 2 auxiliary switches plus 1 trip alarm switch (HQ configuration). The base switch is order code 3VA11635EF320AA0.

Panel fit and integration notes

Dimensions: 130 mm height, 76.2 mm width, 70 mm depth — fits standard SENTRON 3VA panel cutouts and busbar arrangements. Ambient operating range -25 °C to 70 °C; storage range -40 °C to 80 °C. Rated insulation voltage 800 V; maximum power loss 17.3 W at rated load — factor that into enclosure thermal calculations.

MPN
3VA1163-5EF32-0JH0