Skip to main content
Siemens 3VA1163-5EF36-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-5EF36-0AD0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA1163-5EF36-0AD0

Siemens SENTRON 3VA1163-5EF36-0AD0, molded case circuit breaker, 3-pole, 63 A, TM240 thermal-magnetic release, 187 kA at 240 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-5EF36-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1163-5EF36-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1163-5EF36-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1163-5EF36-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-5EF36-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1163-5EF36-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-5EF36-0AD0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

SENTRON 3VA1163-5EF36-0AD0 — 63 A MCCB with TM240 release

The three-pole design carries a rated insulation voltage of 800 V and delivers breaking capacities of 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — numbers that govern selectivity coordination downstream. For a 63 A feeder protecting a fixed load like a panel main or a non-critical motor branch, this is a clean fit; for applications needing coordination curves, the adjustable electronic release variants in the 3VA family are the alternative.

The 17 kA at 690 V still covers most 690 V motor control center bus faults.

Auxiliary contacts and monitoring

This variant ships with three auxiliary switches HQ (high-query type) integrated — no separate add-on module needed. That gives you three independent signal paths for remote status (open/closed/tripped) back to a PLC or indicator panel.

Dimensions are 130 mm high, 76.2 mm wide, 70 mm deep — a standard 3-pole MCCB footprint that drops into most SENTRON distribution blocks and panelboards without re-drilling. The front face is IP40, meaning tools or fingers won't reach live parts, but the sides and back rely on the enclosure for ingress protection. The 63 A rating holds at 40 °C, 45 °C, and 50 °C; above that it derates to 60.48 A at 55 °C and 56.7 A at 70 °C — factor that into panel ambient calculations.

Frequently asked questions

What is the breaking capacity of 3VA1163-5EF36-0AD0 at 415 V?

121 kA at 415 V AC. That covers virtually all industrial distribution fault levels at this voltage.

Does 3VA1163-5EF36-0AD0 have an adjustable trip unit?

No — it uses a fixed TM240 thermal-magnetic release. For adjustable electronic trips, look at the 3VA1 variants with an ETU designation.

What auxiliary contacts come with this MCCB?

Three HQ auxiliary switches are integrated. No separate auxiliary contact block is needed for basic open/closed/trip signaling.

Where can I buy 3VA1163-5EF36-0AD0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA1163-5EF36-0AD0