Skip to main content
Siemens 3VA1163-5MH32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-5MH32-0HC0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA1163-5MH32-0HC0

Siemens SENTRON 3VA1163-5MH32-0HC0, Molded case circuit breaker, 3-pole, 63 A, 187 kA at 240 V, TM120M overcurrent release, shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-5MH32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionStarter protection
Basic switch (supplied) ref.3VA11635MH320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1163-5MH32-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V8.5 kA
3VA1163-5MH32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM120M
Overcurrent protection functionI
3VA1163-5MH32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-5MH32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1163-5MH32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-5MH32-0HC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1163-5MH32-0HC0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient range up to 50 °C, derating to 58 A at 70 °C. The TM120M thermal-magnetic overcurrent release handles the overload and short-circuit trip curves. What sets this one apart is the interrupting capacity: 187 kA at 240 VAC, 121 kA at 415 VAC, and still 75.6 kA at 440 V — that's serious fault-current muscle for high-capacity distribution or large motor branch circuits where the available fault current is high.

Breaking capacity at every voltage

The 3VA1163-5MH32-0HC0 carries 8.5 kA at 690 VAC — enough for 690 V line-ups, but the real story is the low-voltage side. At 240 V it clears 187 kA, so it's a fit for transformer secondaries or busway taps with massive fault current. No second-source I'd bolt in blind — the closest functional peer is the 3VA1010-2ED32-0JA0, but that's a different rating frame and release. Panel rewiring would be required.

Width is 76.2 mm (standard 3-pole MCCB footprint), depth 70 mm, height 130 mm. Front IP40 protection — fine for enclosed panels, not for washdown zones. The two HQ auxiliary switches provide form-C feedback to a PLC or status lamp without an add-on module.

Frequently asked questions

Where can I buy 3VA1163-5MH32-0HC0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — submit an RFQ for a firm commitment.

What is the breaking capacity of 3VA1163-5MH32-0HC0 at 415 V?

121 kA at 415 VAC, which covers most European industrial mains without upstream fusing.

Does 3VA1163-5MH32-0HC0 include a shunt trip?

Yes, it comes with a shunt trip (STL) release as standard, allowing remote tripping from a safety circuit or E-stop chain.

MPN
3VA1163-5MH32-0HC0