Siemens 3VA1163-5MH32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-5MH32-0JC0 Circuit Breaker, 55kA @ 415V, 63A

MPN3VA1163-5MH32-0JC0

Siemens 3VA1 IEC frame 160, breaking capacity class M, Icu=55kA @ 415V, 3-pole, starter protection TM120M, AM, In=63A, without overload protection, short-circuit protection Ii=5...15 x In, nut keeper kit, shunt trip (STL) 110-127V DC/AC 50/60Hz, 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this 3VA1 MCCB carries

The Siemens 3VA1163-5MH32-0JC0 is a 3-pole IEC frame 160 molded case circuit breaker in breaking capacity class M, rated for a 55 kA interrupting capacity at 415 V AC. The thermal-magnetic trip unit is a TM120M set at 63 A (In), configured for starter protection. The description states 'without overload protection' — this unit provides short-circuit protection only (Ii adjustable 5–15 x In). Integrated accessories include a shunt trip (STL) rated for 110–127 V DC or AC 50/60 Hz, plus two HQ auxiliary switches for remote status indication. A nut keeper kit is also included for secure mounting in the panel.

For BOM freeze or PCN watch purposes, this part is a safe line-item commitment. If you are managing a multi-year panel program, the 3VA1 platform is Siemens' current-generation IEC MCCB family, so long-term supply continuity is the baseline expectation.

The nut keeper kit simplifies panel-builder installation — no loose hardware to drop into live gear. The shunt trip coil draws from a 110–127 V control circuit; verify the control transformer secondary matches that range and that the DC rating is observed if using a rectified supply. The two HQ auxiliary switches provide Form C (changeover) contacts for PLC digital inputs or status lamps. They share the breaker's internal mechanism, so no external interposing relays are needed for basic run/ trip indication.

Frequently asked questions

What is the interrupting rating of this breaker?

The Icu (ultimate breaking capacity) is 55 kA at 415 V AC, which is the class M rating on the 3VA1 IEC frame 160 platform.

Does this breaker include overload protection for a motor?

No. The description states 'without overload protection'. The TM120M trip unit provides short-circuit protection only (Ii adjustable 5–15 x In). A separate overload relay must be used in the motor starter circuit.

MPN
3VA1163-5MH32-0JC0