Siemens 3VA1163-5MH36-0AA0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA1163-5MH36-0AA0
Active

Siemens SENTRON molded case circuit breaker, 3VA1163-5MH36-0AA0, 3-pole, 63 A, TM120M thermal-magnetic release, starter protection version, 187 kA interrupting at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-5MH36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionStarter protection

Ratings

3VA1163-5MH36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.17.3 W

Protection & Trip Unit

3VA1163-5MH36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM120M
Overcurrent protection functionI
Ground-fault monitoringWithout

Construction & Connection

3VA1163-5MH36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-5MH36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1163-5MH36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-5MH36-0AA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for motor branch circuits

The Siemens 3VA1163-5MH36-0AA0 is a 3-pole SENTRON molded case circuit breaker rated for 63 A continuous at 40 °C, with a TM120M thermal-magnetic overcurrent release. Its interrupting capacity reaches 187 kA at 240 V and 121 kA at 415 V — figures that provide ample headroom for high-fault installations like large motor control centers or transformer secondaries. The starter protection version tailors the trip curve to motor inrush, so it coordinates with a contactor and overload relay rather than nuisance-tripping on start. Rated insulation voltage is 800 V, and the breaker is rated for 75.6 kA at 440 V, 7.5 kA at 500 V and 690 V. The TM120M release provides fixed thermal and magnetic settings — no field-adjustable trip unit — which simplifies specification and reduces the chance of mis-coordination. Front IP40 protection is adequate for clean panel environments.

Integration and fit

The breaker measures 130 mm high, 76.2 mm wide, and 70 mm deep. It mounts on a standard DIN rail or panel-mount base. The 3-pole footprint matches the 3VA1112-5MH32-0AA0 and other SENTRON 3VA breakers of the same frame size, so a panel designed around that sibling accepts this unit without rewiring — the bus connections, lug centers, and mounting holes are identical.

Frequently asked questions

Will 3VA1163-5MH36-0AA0 drop into a panel specified around 3VA1112-5MH32-0AA0?

Yes. Both breakers share the same 3-pole SENTRON frame size — identical mounting footprint, bus spacing, and DIN-rail clip positions. No rewiring is needed.

MPN
3VA1163-5MH36-0AA0