Siemens 3VA1163-5MH36-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-5MH36-0DC0 Circuit Breaker, 63A, 55kA @ 415V

MPN3VA1163-5MH36-0DC0

Siemens 3VA1 IEC frame 160 circuit breaker, breaking capacity class M, Icu=55kA @ 415V, 3-pole, starter protection TM120M, AM, In=63A, without overload protection, short-circuit protection Ii=5...15 x In, clamp connection, undervoltage release (UVR) 208-230V AC 50/60Hz, 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this 3VA1 breaker carries

The Siemens 3VA1163-5MH36-0DC0 is a 3-pole IEC frame 160 circuit breaker in the 3VA1 series, rated 63 A with a breaking capacity class M delivering Icu=55 kA at 415 V AC. It is configured as a starter-protection device with a TM120M thermal-magnetic release — note the TM120M is set for motor-starting duty, not general distribution — and the short-circuit protection trip threshold Ii is adjustable from 5 to 15 times In. The unit includes an undervoltage release (UVR) for 208–230 V AC, 50/60 Hz, plus two HQ auxiliary switches.

Lifecycle and sourcing posture

For procurement: this part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Deployment context — panel integration

The 3VA1 frame 160 mounts on a DIN rail or panel base in a standard distribution or motor-control center enclosure. The clamp connections accept copper or aluminum conductors; the undervoltage release coil draws from a 208–230 V AC control supply, so verify the control transformer secondary matches that range before wiring. The two HQ auxiliary switches provide status feedback to a PLC or safety relay — typically wired as normally-open for breaker position indication.

Frequently asked questions

What is the breaking capacity of 3VA1163-5MH36-0DC0?

The breaking capacity class M gives Icu=55 kA at 415 V AC, which means it can safely interrupt fault currents up to 55 kA without damage at that voltage level.

Where can I buy 3VA1163-5MH36-0DC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quotation to confirm current availability and pricing.

Does this breaker include overload protection?

No. The description explicitly states 'without overload protection' — the TM120M release provides short-circuit protection only (Ii adjustable 5–15 x In). Overload protection must be provided by a separate overload relay or motor-protective device upstream.