Skip to main content
Siemens 3VA1163-6ED46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-6ED46-0AA0 SENTRON MCCB, 63 A, 4-Pole, TM210

MPN3VA1163-6ED46-0AA0
Active

Siemens SENTRON 3VA1163-6ED46-0AA0, molded case circuit breaker, 4-pole, 63 A at 40 °C, TM210 thermal-magnetic release, 220 kA interrupting at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-6ED46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1163-6ED46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.17.3 W
3VA1163-6ED46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1163-6ED46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-6ED46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1163-6ED46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-6ED46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1163-6ED46-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for line protection, carrying 63 A continuous at 40 °C with no derating through 50 °C — it holds full ampacity across typical panel ambient temps, only dropping to 58 A at 70 °C.

Interrupting ratings and SCCR planning

Interrupting capacity is 220 kA at 240 V, dropping to 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 500 V and 690 V. At 480 V systems the 121 kA at 440 V is the closest published point; for a 480 V panel with available fault current under 100 kA this breaker has headroom.

The 4-pole frame is wider than a 3-pole version — verify panel cutout and busbar spacing if replacing a narrower MCCB. IP40 on the front, so it's suited for dry indoor enclosures; no washdown rating.

Frequently asked questions

What is the interrupting rating of this MCCB at 240 V?

220 kA at 240 V, with 154 kA at 415 V and 121 kA at 440 V.

Where can I buy 3VA1163-6ED46-0AA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What does the TM210 release designation mean?

TM210 is the thermal-magnetic overcurrent release type on this breaker — fixed thermal and magnetic settings, no electronic adjustment. It's the standard release for line-protection duty.

MPN
3VA1163-6ED46-0AA0