Siemens 3VA1163-6EF32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-6EF32-0CC0 SENTRON MCCB, 63 A, 220 kA at 240

MPN3VA1163-6EF32-0CC0

Siemens SENTRON 3VA1163-6EF32-0CC0, molded case circuit breaker, 3-pole, 63 A, TM240 release, 220 kA at 240 V, undervoltage release, 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1163-6EF32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1163-6EF32-0CC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 690 V17 kA

Protection & Trip Unit

3VA1163-6EF32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1163-6EF32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1163-6EF32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1163-6EF32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1163-6EF32-0CC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1163-6EF32-0CC0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 63 A across ambient temperatures from 40 °C to 50 °C without derating. At 55 °C it still holds 60.48 A, and at 70 °C it maintains 56.7 A — so in a warm panel you lose less than 10 % of the rating. The TM240 overcurrent release is fixed-thermal-magnetic, meaning no adjustment dials; the trip curve is set at the factory.

Breaking capacity and coordination

This MCCB delivers 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 690 V. Those are the maximum interrupting ratings at each voltage — the actual available fault current on your bus must be lower for the breaker to clear safely. The 415 V figure (154 kA) is the one most panel builders will check for IEC 60947-2 compliance in a 400 V distribution board. The 690 V rating (17 kA) is notably lower; if your system runs 690 V with high fault potential, verify the SCCR before specifying.

Frequently asked questions

Will 3VA1163-6EF32-0CC0 drop into a panel specified around 3VA1110-5EE32-0DC0 without rewiring?

Both breakers share the same SENTRON 3VA frame size, so the mounting footprint and terminal spacing are identical. The 3VA1163 carries a higher continuous current (63 A vs. the 3VA1110's lower rating) and a different trip unit (TM240 vs. TM210), so the protection curve changes — verify coordination with your downstream devices before swapping.