Siemens 3VA1163-6EF36-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-6EF36-0CA0 SENTRON MCCB, 63 A, 220 kA at 240

MPN3VA1163-6EF36-0CA0

Siemens SENTRON 3VA1163-6EF36-0CA0, 3-pole molded case circuit breaker, 63 A rated continuous current, TM240 overcurrent release, 220 kA breaking capacity at 240 V, line protection version with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1163-6EF36-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1163-6EF36-0CA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 690 V17 kA
3VA1163-6EF36-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1163-6EF36-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1163-6EF36-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1163-6EF36-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1163-6EF36-0CA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Siemens 3VA1163-6EF36-0CA0 — 63 A MCCB with 220 kA SCCR

The Siemens 3VA1163-6EF36-0CA0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C, with a TM240 thermal-magnetic overcurrent release and an integrated undervoltage release (UVR). Its headline breaking capacity of 220 kA at 240 V (154 kA at 415 V, 121 kA at 440 V, 17 kA at 690 V) means it can safely interrupt fault currents up to those levels without cascading upstream — a key spec for high-fault panels where upstream breaker coordination is tight. This is a line protection version (no ground fault monitoring, no phase failure detection, no communication function), designed for straightforward overcurrent and short-circuit protection of feeders and downstream loads.

The 63 A rating holds flat from 40 °C through 50 °C, then derates linearly to 56.7 A at 70 °C — a gentle curve that gives headroom in warm enclosures without oversizing the frame. Latching endurance is 15,000 cycles.

No auxiliary contacts are fitted as standard; the auxiliary trip is a separate order (3VA9608-0BB24) if remote signaling is needed.

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a compact 3-pole frame that fits standard panel cutouts for the 3VA platform. The undervoltage release (UVR) is factory-fitted; verify coil voltage compatibility with your control circuit before installation.

Frequently asked questions

Does the 3VA1163-6EF36-0CA0 include auxiliary contacts?

No, the auxiliary contact version is without. If remote status signaling is required, the separate auxiliary trip order code is 3VA9608-0BB24.

What is the physical size of the 3VA1163-6EF36-0CA0?

The dimensions are 130 mm height, 76.2 mm width, and 70 mm depth.

MPN