Siemens 3VA1163-6MH32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-6MH32-0CA0 Circuit Breaker, 63A, 70kA @ 415V

MPN3VA1163-6MH32-0CA0

Siemens 3VA1 IEC frame 160 circuit breaker, breaking capacity class H, Icu=70kA @ 415V AC, 3-pole, 63A, starter protection TM120M, with undervoltage release 120-127V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

Siemens 3VA1163-6MH32-0CA0 — 63A IEC Frame 160 Circuit Breaker with Undervoltage Release

The Siemens 3VA1163-6MH32-0CA0 is a 3-pole IEC frame 160 circuit breaker rated 63 A with a breaking capacity class H — Icu of 70 kA at 415 V AC. That 70 kA interrupting rating means it can safely clear a fault current up to that level without upstream devices needing to trip, which is what makes it suitable for high-fault installations like industrial main feeders or large motor control centers. This variant is configured for starter protection with a TM120M thermal-magnetic trip unit, but note the description explicitly states it provides short-circuit protection only — no overload protection is included. The short-circuit pickup Ii is adjustable 5 to 15 x In (315 A to 945 A). It also ships with a nut keeper kit and an undervoltage release (UVR) rated 120-127 V AC, 50/60 Hz. Mounts on standard DIN rail or panel-mount within the 3VA1 enclosure family. The UVR coil holds at 120-127 V AC; below dropout voltage the breaker trips, which is typical for emergency-stop or undervoltage protection schemes where loss of control power must open the main circuit.

Integration Notes

The 3VA1 frame accepts plug-in accessories like auxiliary contacts, shunt trips, and alarm switches — the UVR here occupies one accessory slot. Verify the nut keeper kit is installed before torquing busbar connections; it prevents hardware migration under vibration. At 63 A on a 160 A frame, thermal rise is well within limits — the larger frame gives headroom for higher ambient temperatures or enclosed panel mounting without derating concerns. The class H breaking capacity (70 kA @ 415 V) exceeds typical 25-50 kA requirements for most industrial distribution, so selectivity coordination with downstream breakers is straightforward.

Frequently asked questions

What is the breaking capacity of 3VA1163-6MH32-0CA0?

The breaking capacity class H gives an Icu of 70 kA at 415 V AC. That is the maximum short-circuit current the breaker can safely interrupt at that voltage level.

Does this breaker include overload protection?

No — the description specifies starter protection with short-circuit protection only (Ii adjustable 5-15 x In). Overload protection is not provided by this variant; it relies on an external overload relay or motor starter.

What voltage does the undervoltage release require?

The UVR is rated 120-127 V AC, 50/60 Hz. Below dropout voltage the breaker trips, providing undervoltage protection.

Where can I buy 3VA1163-6MH32-0CA0 and get current pricing?

Sourced and quoted to order against an RFQ through our independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.