Siemens 3VA1163-6MH32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-6MH32-0JA0 IEC MCCB, 70 kA @ 415 V, 63 A

MPN3VA1163-6MH32-0JA0

Siemens 3VA1 IEC frame 160, breaking capacity class H, 70 kA @ 415 V, 3-pole, TM120M, 63 A, shunt trip 110-127 V DC/AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The 3VA1163-6MH32-0JA0 is a 3-pole IEC frame 160 MCCB from the Siemens 3VA1 series, rated 63 A with a TM120M thermal-magnetic trip unit. The magnetic short-circuit pickup is adjustable from 5 to 15× In. This variant ships without overload protection — the TM120M provides short-circuit protection only, with the thermal element omitted. That's deliberate: it's meant for starter-protection duty where the upstream overload relay handles the thermal curve. Pair it with a properly sized contactor and overload for motor branch circuits. The integrated shunt trip (STL) operates on 110–127 V DC or AC, 50/60 Hz. That's a remote-trip coil — energize it and the breaker opens instantly. Typical use: emergency-stop circuit, fire-alarm shunt, or a PLC-driven safe-state signal that kills power to the motor control center. A nut keeper kit is included in the box — that's the hardware to retain the terminal nuts on the line/load lugs so vibration on a mill or conveyor frame doesn't back them off. Built for the pit, not the panel shop.

The 3-pole footprint is compact for the 70 kA rating — roughly the same width as a standard 160 A frame. Leave clearance above and below for the arc-chute exhaust; Siemens specifies minimum 100 mm free air for the gas vent. The shunt trip terminals are separate from the main power lugs. Verify the control voltage matches your panel's 110–127 V supply before energizing.

Frequently asked questions

What is the breaking capacity of this MCCB?

Icu = 70 kA at 415 V AC. That's the maximum short-circuit current it can safely interrupt once without damage — suitable for high-fault-capacity industrial panels.

Does this breaker include overload protection?

No. The TM120M trip unit provides short-circuit (magnetic) protection only, with the thermal element omitted. It is designed for starter-protection duty where an external overload relay handles the thermal curve.

What voltage does the shunt trip require?

The integrated shunt trip operates on 110–127 V DC or AC, 50/60 Hz. Energizing the coil trips the breaker remotely.