Skip to main content
Siemens 3VA1163-6MH36-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-6MH36-0BA0 Circuit Breaker, 70kA @ 415V, 63A

MPN3VA1163-6MH36-0BA0

Siemens 3VA1 IEC frame 160, breaking capacity class H, Icu=70kA @ 415V, 3-pole, 63A, starter protection TM120M, AM, clamp connection, undervoltage release (UVR) 24V DC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA1163-6MH36-0BA0 is a 3-pole IEC frame 160 circuit breaker with breaking capacity class H — meaning it interrupts 70 kA at 415 V without welding or damage. That 70 kA SCCR gives you headroom for high-fault panels where a standard 25 kA or 36 kA breaker would cascade upstream. Rated In = 63 A, with a TM120M thermal-magnetic trip unit set for starter protection (motor branch circuit). The adjustable short-circuit pickup Ii = 5...15 × In lets you coordinate with downstream contactors and overloads without nuisance tripping on inrush. This variant ships without overload protection — it is a magnetic-only short-circuit protector for use ahead of a separate overload relay. The undervoltage release (UVR) coil is 24 V DC; if that control voltage drops, the breaker opens instantly, which is standard for emergency-stop chains or undervoltage protection schemes on conveyor lines.

Deployment context

Mounts on a standard DIN rail or panel-mount via the 3VA1 frame's integral latching mechanism. The clamp terminals accept copper or aluminium conductors up to the frame's rated cross-section — no lug kit required for the main power connections. The UVR coil draws a few milliamps at 24 V DC; verify your control transformer can supply the holding current without a separate power supply.

Frequently asked questions

What is the breaking capacity of 3VA1163-6MH36-0BA0?

The breaking capacity is class H with Icu = 70 kA at 415 V AC. That is the maximum short-circuit current the breaker can safely interrupt at that voltage level.

Does 3VA1163-6MH36-0BA0 include overload protection?

No. This variant is specified without overload protection — it provides only short-circuit protection via the TM120M thermal-magnetic trip unit. You must add a separate overload relay upstream or downstream for motor overload protection.

Where can I buy 3VA1163-6MH36-0BA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN