Siemens 3VA1163-6MH36-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1163-6MH36-0CA0 Circuit Breaker, 70kA @ 415V, 63A

MPN3VA1163-6MH36-0CA0

Siemens 3VA1 IEC frame 160 circuit breaker, breaking capacity class H, Icu=70kA @ 415V, 3-pole, starter protection TM120M, In=63A, undervoltage release 120-127V AC, clamp connection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this breaker does on the line

The Siemens 3VA1163-6MH36-0CA0 is a 3-pole IEC frame 160 circuit breaker with a 70 kA breaking capacity at 415 V (class H), rated at 63 A. It is configured for starter protection with a TM120M thermal-magnetic release — meaning the thermal element is sized for motor-starting inrush and the magnetic short-circuit pickup is adjustable from 5 to 15 times In. This breaker does not include overload protection (the TM120M provides only short-circuit protection), so it pairs with a separate overload relay in a motor starter assembly. The built-in undervoltage release (UVR) operates on 120–127 V AC, 50/60 Hz, and will trip the breaker if control voltage drops, which is standard for safety circuits that need to drop out on loss of control power.

Panel integration and wiring

Clamp-type terminals accept copper conductors without lugging — strip length and torque follow the Siemens 3VA1 mounting instructions. The breaker snaps onto DIN rail (EN 60715) and occupies a 3-pole width in the panel. The UVR coil draws continuously when energized; verify the control transformer is sized for the holding current plus any other loads on the same 120 V AC circuit.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA1163-6MH36-0CA0 is rated Icu = 70 kA at 415 V AC, which is breaking capacity class H in the 3VA1 frame. This means it can safely interrupt fault currents up to 70,000 A at that voltage without external fusing.

Does this breaker include overload protection?

No. The TM120M release provides only short-circuit protection with adjustable magnetic pickup (Ii = 5–15 × In). A separate overload relay is required for motor overload protection in a starter configuration.

What voltage does the undervoltage release require?

The UVR operates on 120–127 V AC, 50/60 Hz. If control voltage drops below the dropout threshold, the breaker trips immediately.

Where can I buy 3VA1163-6MH36-0CA0 and get current pricing?

This part is sourced to order against an RFQ through our independent distribution channels. Submit a request for quote to confirm current availability and pricing — no stock figures or lead-time numbers are published here.