Skip to main content
Siemens 3VA1180-3ED32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-3ED32-0AA0 SENTRON MCCB, 80 A, 3-Pole

MPN3VA1180-3ED32-0AA0
Active

Siemens SENTRON 3VA1180-3ED32-0AA0, molded case circuit breaker, 3-pole, 80 A continuous at 40 °C, TM210 thermal-magnetic release, interrupting capacity 75.6 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-3ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1180-3ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.2 W
3VA1180-3ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1180-3ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-3ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1180-3ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-3ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1180-3ED32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated 80 A continuous at 40 °C, fitted with a TM210 thermal-magnetic release for line protection. It's designed for distribution panels and motor branch circuits where you need adjustable thermal pickup and fixed magnetic instant trip — the TM210 gives you a 2:1 thermal adjustment range (0.7–1.0× In) and a fixed magnetic trip at 10× In, so it handles motor inrush without nuisance trips on the thermal side. Interrupting capacity runs 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500 V and 690 V — that covers most industrial service entrances and sub-distribution boards without needing a current-limiting fuse upstream.

At 130 mm high, 76.2 mm wide, and 70 mm deep, this MCCB fits a standard 3-pole breaker slot in most Siemens SENTRON panelboards and switchgear. The 76.2 mm width matches the 3-inch (76.2 mm) modular spacing common in North American panel schedules — you can swap it into an existing 3-pole position without re-drilling the mounting plate.

Above 50 °C it drops linearly: 78 A at 55 °C, 77 A at 60 °C, 75 A at 65 °C, 74 A at 70 °C. If your panel ambient hits 70 °C, you've still got 74 A of headroom. In a sealed NEMA 4X box with multiple breakers, add those losses up for the thermal budget.

Frequently asked questions

Where can I buy 3VA1180-3ED32-0AA0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the interrupting capacity of 3VA1180-3ED32-0AA0 at 240 V?

75.6 kA at 240 V. At 415 V it's 52.5 kA, at 440 V it's 32 kA, and at 500 V and 690 V it's 11.9 kA.

Does 3VA1180-3ED32-0AA0 have a communication function or undervoltage release?

No. This variant has no communication function, no undervoltage release, no shunt trip, and no ground-fault monitoring. It's a straight thermal-magnetic breaker for line protection.

MPN
3VA1180-3ED32-0AA0