Skip to main content
Siemens 3VA1180-3ED42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-3ED42-0AA0 SENTRON MCCB, 80 A, 4-Pole, TM210

MPN3VA1180-3ED42-0AA0
Active

Siemens SENTRON 3VA1180-3ED42-0AA0, molded case circuit breaker, 4-pole, 80 A, TM210 thermal-magnetic release, line protection version, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-3ED42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1180-3ED42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.2 W
3VA1180-3ED42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1180-3ED42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-3ED42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1180-3ED42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-3ED42-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The 3VA1180-3ED42-0AA0: The 80 A rating holds flat from 40 °C through 50 °C, then derates to 78 A at 55 °C, 77 A at 60 °C, 75 A at 65 °C, and 74 A at 70 °C. The unit measures 101.6 mm wide by 130 mm tall by 70 mm deep, which is a standard SENTRON 4-pole footprint; it mounts via screw terminals to a backplate or DIN rail adapter, not a snap-on DIN clip.

Frequently asked questions

What is the closest functional alternative to 3VA1180-3ED42-0AA0?

The 3VA1010-2ED32-0AD0 is a smaller-frame 3VA variant, but it is a 3-pole unit with a different release — it will not drop into a 4-pole panel position without rewiring the neutral conductor. For a 4-pole 80 A replacement, stay within the 3VA1180 frame family.

Where can I buy 3VA1180-3ED42-0AA0 and how is it quoted?

We source this MCCB to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What are the panel dimensions for 3VA1180-3ED42-0AA0?

The breaker measures 101.6 mm wide, 130 mm tall, and 70 mm deep — a standard SENTRON 4-pole footprint that fits most low-voltage distribution boards.

MPN
3VA1180-3ED42-0AA0