Skip to main content
Siemens 3VA1180-3ED46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-3ED46-0AA0 SENTRON MCCB, 80 A, 4-Pole, TM210

MPN3VA1180-3ED46-0AA0
Active

Siemens SENTRON 3VA1 molded case circuit breaker, 80 A, 4-pole, TM210 thermal-magnetic release, line protection, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-3ED46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1180-3ED46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.2 W
3VA1180-3ED46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1180-3ED46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-3ED46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1180-3ED46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-3ED46-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

It's built for distribution panels where you need a fixed, non-communicating MCCB that clears faults fast: 75.6 kA at 240 V, 52.5 kA at 415 V, and still 11.9 kA at 690 V. The 80 A rating holds steady from 40 °C up to 50 °C, then derates to 74 A at 70 °C — so if your panel runs hot, you still have margin. No trip indicator, no voltage trigger, no ground-fault monitoring — this is a straight-ahead thermal-magnetic breaker for main or feeder protection.

Sizing and thermal reality

The 80 A continuous current (Iu) is what you spec against. At 55 °C it's 78 A; at 60 °C it's 77 A; at 65 °C it's 75 A; at 70 °C it's 74 A. No adjustment range, no electronic trip — set it and forget it.

Panel fit and environment

Four-pole footprint — it takes up the same width as a standard 4-pole MCCB on the DIN rail or mounting plate. Power loss maxes at 19.2 W — factor that into your enclosure thermal calc if you're stacking several breakers side by side.

Frequently asked questions

What is the breaking capacity of this MCCB at 415 V?

At 415 V the rated breaking capacity is 52.5 kA. At 240 V it's 75.6 kA, at 440 V it's 32 kA, and at 500 V or 690 V it's 11.9 kA.

Does this breaker have a trip indicator or ground-fault monitoring?

No. The 3VA1180-3ED46-0AA0 has no trip indicator, no voltage trigger, no undervoltage release, and no ground-fault monitoring. It's a straight thermal-magnetic line protection breaker.

Where can I buy 3VA1180-3ED46-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
3VA1180-3ED46-0AA0