Siemens 3VA1180-3EE32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-3EE32-0AA0 SENTRON MCCB, 80 A, 3-Pole, 800 A

MPN3VA1180-3EE32-0AA0
Active

Siemens SENTRON 3VA1180-3EE32-0AA0, molded case circuit breaker, 3-pole, 80 A continuous rating, 800 A frame, TM220 thermal-magnetic release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-3EE32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1180-3EE32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.2 W
3VA1180-3EE32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1180-3EE32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-3EE32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1180-3EE32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-3EE32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1180-3EE32-0AA0 is a 3-pole molded case circuit breaker rated for 80 A continuous current at 40 °C, built on an 800 A frame. That frame size tells you the internal mechanism and contacts are physically sized for 800 A — the breaker is thermally-magnetically limited to 80 A by its TM220 trip unit, so it's a line-protection device, not a feeder breaker. The interrupting ratings climb as voltage drops: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at both 500 V and 690 V. The breaker's dimensions — 130 mm high, 76.2 mm wide, 70 mm deep — fit the standard SENTRON 3VA panel footprint. That 76.2 mm width (3 inches) is the same as other 3VA frame sizes in this range, so it swaps into an existing 3VA mounting base without re-drilling the panel. The 70 mm depth keeps it clear of most gland plates and backpanel wiring troughs.

Thermal Derating — Where the 80 A Rating Holds and Where It Doesn't

Above 50 °C it steps down: 78 A at 55 °C, 77 A at 60 °C, 75 A at 65 °C, and 74 A at 70 °C. That's about a 7.5% drop from 50 °C to 70 °C, which is modest for a thermal-magnetic breaker. If your enclosure sits near a furnace or in a hot attic, size the load at 74 A maximum to avoid nuisance tripping on a 70 °C ambient day.

How It Sits Against the 3VA1110-5ED32-0AA0

The 3VA1110-5ED32-0AA0 is a different frame size and rating within the same 3VA family. The 3VA1180-3EE32-0AA0 uses an 800 A frame with an 80 A TM220 trip; the 3VA1110 series typically uses a smaller frame (likely 160 A or 250 A) with a different trip curve. The wiring lugs and bus-bar connections, however, differ by frame ampacity: the 800 A frame has larger line/load terminals than a 160 A frame. If your existing panel was wired for a 3VA1110-5ED32-0AA0, the 3VA1180-3EE32-0AA0 will bolt to the same mounting holes but may require different lug sizes or bus-bar adapters for the higher frame rating. That's another SKU to check before the line-down swap.

Frequently asked questions

What is 3VA1180-3EE32-0AA0's listed depth?

The depth is 70 mm (2.76 in). That keeps it clear of most gland plates and backpanel wiring troughs in a standard enclosure.

What is 3VA1180-3EE32-0AA0's listed width?

The width is 76.2 mm (3 in). This matches the standard 3VA panel footprint, so it swaps into an existing 3VA mounting base without re-drilling.

Will 3VA1180-3EE32-0AA0 drop into a panel specified around 3VA1110-5ED32-0AA0 without rewiring?

The physical footprint (76.2 mm width, 130 mm height) is shared across many 3VA frame sizes, so it bolts to the same mounting holes. However, the 800 A frame uses larger line/load terminals than the smaller 3VA1110 frame — check lug sizes and bus-bar adapters before the swap.

MPN
3VA1180-3EE32-0AA0