Siemens 3VA1180-3EE36-0AA0 SENTRON MCCB, 80 A, 3-Pole, TM220

MPN3VA1180-3EE36-0AA0
Active

Siemens SENTRON 3VA1180-3EE36-0AA0, molded case circuit breaker, 3-pole, 80 A, TM220 thermal-magnetic release, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-3EE36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1180-3EE36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.2 W
3VA1180-3EE36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1180-3EE36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-3EE36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1180-3EE36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-3EE36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It breaks up to 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at both 500 V and 690 V — so it handles fault-clearing across common industrial voltage levels without cascading upstream. The operating temperature range of -25 °C to 70 °C means it takes the radiant heat near a rolling mill without derating until you push past 55 °C, where the current rating steps down from 80 A to 78 A at 55 °C, 77 A at 60 °C, 75 A at 65 °C, and 74 A at 70 °C.

The 3VA1180-3EE36-0AA0 measures 76.2 mm wide, 130 mm tall, and 70 mm deep — a compact 3-pole footprint that fits standard MCCB panel cutouts. It is a line-protection device with no undervoltage release, no trip indicator, no communication function, and no ground-fault monitoring, so it is a straightforward thermal-magnetic breaker for feeder or branch-circuit protection. The TM220 release gives a fixed thermal and magnetic trip curve suited for cable and distribution protection rather than motor-starting duty.

Frequently asked questions

What is the breaking capacity of this MCCB at 415 V?

At 415 V the breaking capacity is 52.5 kA, which is sufficient for most industrial distribution panels with moderate fault current levels.

Where can I buy 3VA1180-3EE36-0AA0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

What is the rated continuous current of this breaker?

The rated continuous current is 80 A, with a thermal derating curve that holds 80 A up to 50 °C, then steps down to 78 A at 55 °C, 77 A at 60 °C, 75 A at 65 °C, and 74 A at 70 °C.

MPN