Siemens 3VA1180-3EF36-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-3EF36-0HH0 Circuit Breaker, 80A, 25kA @ 415V

MPN3VA1180-3EF36-0HH0

Siemens 3VA1 IEC frame 160, 3-pole MCCB, 80 A, breaking capacity class N Icu=25 kA @ 415 V, TM240 thermal-magnetic trip, shunt trip STL 12-30 V DC / 24 V AC, 2 auxiliary switches HQ + 1 trip alarm switch HQ, clamp connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1180-3EF36-0HH0 is a 3-pole IEC molded-case circuit breaker on the 3VA1 frame, rated 80 A continuous with a 25 kA interrupting capacity at 415 V (class N). It carries a TM240 thermal-magnetic trip unit — the thermal element adjustable from 56 to 80 A, the magnetic pickup fixed at 5 to 10 times In. That means for a motor feeder or distribution panel, you set the Ir dial to match the load current, and the instantaneous trip stays above inrush so nuisance trips don't pull you out of a shift. The shunt trip lets a remote pushbutton or safety relay drop the breaker under load — useful for emergency-stop circuits or remote disconnect in a pump house. The auxiliary switches track the breaker position for PLC status inputs; the alarm switch signals only when the breaker trips on fault, not when it's manually opened.

It's not a high-rupturing-capacity main; it's a feeder or branch breaker. The clamp (lug) connection accepts copper or aluminum conductors, typical for panel-board and motor-control-center wiring. The 3VA1 frame is a compact IEC design — it fits the standard DIN-rail or panel-mount footprint without eating up enclosure space.

Integration notes

The shunt trip coil draws power from a separate control circuit — verify the supply voltage matches the 12–30 V DC or 24 V AC rating before wiring. The auxiliary switches and alarm switch are factory-installed; no field-add kit needed. For coordination studies, the TM240 trip curve is published in the Siemens selectivity manual; the thermal adjustment band (56–80 A) lets you dial in the exact overload protection for the downstream load without changing the breaker.

Frequently asked questions

Where can I buy the 3VA1180-3EF36-0HH0 and what is the lead time?

This breaker is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price.

What is the breaking capacity of this breaker?

The 3VA1180-3EF36-0HH0 has an Icu of 25 kA at 415 V AC, which is breaking capacity class N on the IEC 60947-2 scale.

What does the TM240 trip unit mean?

TM240 is a thermal-magnetic trip with a 240 A frame rating. The thermal overload (Ir) is adjustable from 56 to 80 A, and the magnetic short-circuit pickup (Ii) is fixed at 5 to 10 times In (400 to 800 A for this 80 A breaker).

Does this breaker include a shunt trip and auxiliary contacts?

Yes. It comes with a shunt trip (STL) rated 12–30 V DC or 24 V AC, two auxiliary switches (HQ), and one trip alarm switch (HQ).

MPN
3VA1180-3EF36-0HH0