Siemens 3VA1180-3GD42-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-3GD42-0AA0-ZD00 SENTRON MCCB, 80A, 25kA @ 41

MPN3VA1180-3GD42-0AA0-ZD00

Siemens SENTRON 3VA1 IEC frame 160 molded case circuit breaker, breaking capacity class N, Icu=25kA @ 415V AC, 4-pole, line protection TM210, In=80A, fixed short-circuit protection Ii=10 x In, N conductor protection 100%, DC Power OEM variant.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1180-3GD42-0AA0-ZD00 — Identification
ParameterValue
Brand / rangeSENTRON

Product details

What this 3VA1 MCCB is and what it does

The Siemens SENTRON 3VA1180-3GD42-0AA0-ZD00 is a 4-pole molded case circuit breaker (MCCB) on the 3VA1 IEC frame, rated at 160 A frame size. It carries a breaking capacity class N with Icu = 25 kA at 415 V AC, meaning it can safely interrupt fault currents up to that level on a 415 V line without upstream cascading. The TM210 thermal-magnetic release is set at In = 80 A, with fixed overload protection Ir = 80 A and fixed short-circuit protection Ii = 10 × In (800 A). That fixed trip means no field adjustment — what you order is what you get, which simplifies BOM consistency but locks the protection curve.

Line protection with N-conductor coverage

This breaker is configured for line protection (LI characteristic — long-time and instantaneous) with 100 % N conductor protection. The fourth pole switches the neutral, and the 100 % rating means the neutral path is protected at the same ampacity as the phase conductors. That matters for panels feeding single-phase loads off a three-phase supply where neutral current can approach phase current. The fixed Ir = 80 A and Ii = 10 × In are factory-set; no dials to mis-calibrate on site.

DC Power OEM variant — what that means

The suffix ZD00 designates a DC Power OEM variant produced for the Chinese market. The breaker includes a nut keeper kit for DC power applications. While the AC breaking capacity is specified at 25 kA @ 415 V, the DC performance depends on the system voltage and configuration — the 3VA device manual covers the DC derating curves. If you are sourcing this for a DC bus or battery bank, verify the DC voltage and pole configuration against the manual before committing the BOM line.

Panel integration notes

This is a 4-pole MCCB on the 3VA1 frame. It uses lug terminals for the main current circuit, accepting conductor cross-sections from 12 × 0 mm up to 17 × 6.5 mm (width × thickness). Front-terminal arrangement keeps wiring accessible in a standard panel layout. The IP40 front protection means it is splash-resistant on the face but not sealed for washdown — mount inside a cabinet with a higher enclosure rating if the environment is wet or dusty.

How it compares to the 3-pole 3VA1010-2ED32-0JA0

The closest functional peer in the 3VA1 family is the 3VA1010-2ED32-0JA0, a 3-pole, 100 A frame MCCB with a TM210 release and shunt trip. The key difference for a panel swap: the 3VA1010 is three poles only, no neutral switching, and its Icu at 415 V is higher at 32 kA versus 25 kA on this 4-pole unit. Physically, the 3-pole variant is 76.2 mm wide; the 4-pole unit is wider to accommodate the fourth pole. It will not drop into a 3-pole panel cutout without a mounting adapter or rework of the bus bars.

Frequently asked questions

What is the breaking capacity of this MCCB?

The rated ultimate short-circuit breaking capacity Icu is 25 kA at 415 V AC, which is class N on the 3VA1 frame.

Can I use 3VA1180-3GD42-0AA0-ZD00 to replace a 3VA1010-2ED32-0JA0 in an existing panel?

Not without panel rework. The 3VA1010 is a 3-pole, 100 A unit with a 32 kA rating, while this is a 4-pole, 80 A unit with 25 kA. The width and bus-bar arrangement differ, so a direct drop-in is not possible.

Where can I buy 3VA1180-3GD42-0AA0-ZD00 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What does the TM210 release mean on this breaker?

TM210 is a thermal-magnetic release with a fixed long-time pickup Ir = 80 A and a fixed instantaneous pickup Ii = 10 × In (800 A). It provides LI (line protection) characteristic — no ground-fault or short-time delay functions.