Siemens 3VA1180-3GD46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-3GD46-0AA0 SENTRON MCCB, 80 A, 4-Pole, TM210

MPN3VA1180-3GD46-0AA0
Active

Siemens SENTRON 3VA1180-3GD46-0AA0, molded case circuit breaker, 4-pole, 80 A, TM210 overcurrent release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-3GD46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1180-3GD46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.2 W
3VA1180-3GD46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1180-3GD46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-3GD46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1180-3GD46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-3GD46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The 80 A rating holds flat from 40 °C up to 50 °C, then derates to 74 A at 70 °C.

This breaker can safely clear a fault at 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500 V and 690 V. The 240 V figure is the highest — so if your service entrance or main panel feeds from a 240 V transformer, you have a lot of headroom for high-fault scenarios.

Fit and footprint

The IP40 front face keeps dust and incidental contact out, but it's not washdown-rated; keep it inside the cabinet.

Frequently asked questions

Where can I buy 3VA1180-3GD46-0AA0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm availability and current pricing.

Will 3VA1180-3GD46-0AA0 drop into a panel that was specified around 3VA1010-2ED32-0JA0 without rewiring?

No — the 3VA1010-2ED32-0JA0 is a different frame size and rating. The 3VA1180-3GD46-0AA0 is a 4-pole, 80 A MCCB with a TM210 release, while the 3VA1010 is a smaller 3-pole unit. Panel layout and wiring would need to be re-evaluated.

What compliance documentation does this brand provide for 3VA1180-3GD46-0AA0?

Siemens typically provides RoHS, REACH, UL, and IEC compliance documentation for SENTRON series MCCBs. Specific declarations are available on request or through the manufacturer's support portal.

MPN