Siemens 3VA1180-4ED36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-4ED36-0AA0 SENTRON MCCB, 80A, 3-Pole, 121kA

MPN3VA1180-4ED36-0AA0
Active

Siemens SENTRON 3VA1180-4ED36-0AA0, molded case circuit breaker, 3-pole, 80 A, TM210 thermal-magnetic trip unit, 121 kA interrupting capacity at 240 V AC, line protection design.

$114.30Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-4ED36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1180-4ED36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.2 W
3VA1180-4ED36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1180-4ED36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-4ED36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1180-4ED36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-4ED36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens 3VA1180-4ED36-0AA0 is a 3-pole molded case circuit breaker from the SENTRON 3VA series, rated for 80 A continuous current at 40 °C ambient. It is fitted with a TM210 thermal-magnetic trip unit — a fixed, non-interchangeable design that provides inverse-time overload protection and instantaneous short-circuit response. This variant is designated for line protection, meaning it is intended to protect cable and busbar feeders, not motor or generator circuits. With an interrupting capacity of 121 kA at 240 V AC and 75.6 kA at 415 V, this breaker handles high available fault currents typical in industrial switchboards and panelboard mains. The rating holds at 80 A through 50 °C, then derates to 78 A at 55 °C and 74 A at 70 °C — useful to know when the breaker is mounted in a warm enclosure alongside other heat sources.

For a 3-pole breaker feeding a 3-phase load, that is 80 A per phase. The TM210 trip unit uses a bimetal element for the thermal curve and a solenoid for magnetic instantaneous pickup — the '210' designation indicates the frame size and trip technology, not an adjustable rating. Interrupting ratings drop with voltage: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 500 V or 690 V. This is the SCCR (short-circuit current rating) the panel designer uses for the series rating or fully-rated coordination study. Power loss is 19.2 W maximum — a figure that matters for thermal management inside a sealed enclosure. The IP40 rating on the front means protection against solid objects over 1 mm (tools, wires), but no water ingress protection; the breaker is intended for dry indoor panel mounting.

The 76.2 mm width is a 3-module (3 x 25.4 mm) footprint, standard for DIN-rail mounted MCCBs in this class. The 70 mm depth means it projects less than 3 inches from the mounting surface — important when the panel door clearance is tight.

This is a current-production part with no announced end-of-life. The SENTRON 3VA platform is Siemens' main MCCB family, so spares and replacements are straightforward to source. For a BOM freeze or critical-spare holding, this part is a safe choice — no last-time-buy clock ticking.

Frequently asked questions

What is the interrupting capacity of this MCCB at 415 V?

At 415 V AC, the 3VA1180-4ED36-0AA0 has an interrupting capacity of 75.6 kA. At 240 V it is 121 kA, and at 690 V it is 11.9 kA.

Where can I buy 3VA1180-4ED36-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the continuous current rating of this breaker at elevated temperatures?

Rated 80 A continuous from 40 °C to 50 °C. It derates to 78 A at 55 °C, 77 A at 60 °C, 75 A at 65 °C, and 74 A at 70 °C. Above 70 °C is outside the operating range.

Will 3VA1180-4ED36-0AA0 drop into a panel specified around 3VA1010-2ED32-0JA0 without rewiring?

Both are 3-pole SENTRON 3VA series MCCBs with the same 76.2 mm width and DIN-rail mounting, so the physical footprint is identical. However, the 3VA1010-2ED32-0JA0 is a different frame size and rating — verify the trip unit and interrupting requirements before substituting. No wiring change is needed for the line and load connections if the lug sizes match.

MPN
3VA1180-4ED36-0AA0