Siemens 3VA1180-4EF32-0AA0 SENTRON MCCB, 80A 3-Pole, 121kA a

MPN3VA1180-4EF32-0AA0
Active

Siemens SENTRON 3VA1180-4EF32-0AA0, molded case circuit breaker, 3-pole, 80 A, TM240 thermal-magnetic release, line protection design, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1180-4EF32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1180-4EF32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.2 W

Protection & Trip Unit

3VA1180-4EF32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1180-4EF32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1180-4EF32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1180-4EF32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1180-4EF32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA1180-4EF32-0AA0 — 80 A MCCB with TM240 Release

The Siemens SENTRON 3VA1180-4EF32-0AA0 is a 3-pole molded case circuit breaker rated at 80 A continuous, fitted with a TM240 thermal-magnetic overcurrent release. It's designed for line protection in distribution panels and industrial switchboards — the kind of main or feeder breaker you spec into a 400 VAC bus and forget about, provided the interrupting capacity matches the available fault current. Breaking capacity is the headline here: 121 kA at 240 VAC, 75.6 kA at 415 VAC, and still 11.9 kA at 690 VAC. That 75.6 kA at 415 V covers most European and Asian industrial networks without needing a current-limiting upstream device. At 690 V the 11.9 kA figure is adequate for many motor-control-center infeeds but should be checked against the transformer's nameplate impedance. The TM240 release means the thermal element is fixed at 80 A (the breaker's frame rating) and the magnetic pickup is adjustable — typical range is 5x to 10x In, though the exact setting depends on the variant. No undervoltage release, no shunt trip, no communication module on this order code; it's a straight electromechanical MCCB for hardwired panels where remote tripping isn't required.

Current Derating and Panel Fit

The 80 A rating holds from 40 °C through 50 °C ambient — no derating needed in a typical 40 °C switchroom. At 55 °C it drops to 78 A, at 65 °C to 75 A, and at the 70 °C maximum operating ambient it still carries 74 A. That's a shallow derating curve; you can push ambient without losing much headroom. Physical footprint: 76.2 mm wide (3 in), 130 mm tall, 70 mm deep. That's a standard 3-pole MCCB width — drops into a SENTRON panelboard or a DIN-rail mounting plate without surprises. The front face carries IP40 protection, so it's fine in a closed cabinet; no washdown rating on this variant.

Lifecycle and Sourcing

For a BOM line that needs this exact interrupting capacity and TM240 release, the 3VA1180-4EF32-0AA0 is the direct fit. Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

Frequently asked questions

What is the breaking capacity of 3VA1180-4EF32-0AA0 at 415 V?

75.6 kA at 415 VAC, which covers most European and Asian industrial distribution networks without requiring an upstream current-limiting device.

Where can I buy 3VA1180-4EF32-0AA0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Does 3VA1180-4EF32-0AA0 have a shunt trip or undervoltage release?

No — this order code does not include an undervoltage release, shunt trip, or communication module. It is a straight electromechanical MCCB for hardwired panels.

What is the width of 3VA1180-4EF32-0AA0?

76.2 mm (3 in), which is the standard 3-pole MCCB width for SENTRON panelboards and DIN-rail mounting plates.

MPN
3VA1180-4EF32-0AA0