Skip to main content
Siemens 3VA1180-4EF32-0DC0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1180-4EF32-0DC0 MCCB, 3-pole, 80 A, 121 kA at 240

MPN3VA1180-4EF32-0DC0

Siemens SENTRON 3VA1180-4EF32-0DC0, molded case circuit breaker, 3-pole, 80 A, interrupting rating 121 kA at 240 VAC, 75.6 kA at 415 VAC, line protection design with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-4EF32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11804EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1180-4EF32-0DC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.21.7 W
3VA1180-4EF32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1180-4EF32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-4EF32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1180-4EF32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-4EF32-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this 3VA1180-4EF32-0DC0 brings to a panel

The Siemens SENTRON 3VA1180-4EF32-0DC0 is a 3-pole molded case circuit breaker rated for 80 A continuous at 40 °C, with full rating held up to 50 °C before a gradual derating curve kicks in — at 65 °C it still carries 75 A. That means it handles a warm enclosure without dropping ampacity early, which matters when the panel is packed or near a heat source. Interrupting capacity is the real headline here: 121 kA at 240 VAC, 75.6 kA at 415 VAC, and still 52.5 kA at 440 VAC.

This breaker is a drop-in for panels built around the SENTRON 3VA frame. The 80 A rating and high interrupting capacity suit main feeder protection up to 690 V.

Integration and mounting notes

At 70 mm deep and 76.2 mm wide, it fits alongside other 3VA breakers in a multi-pole lineup without crowding the gland plate. Maximum power loss is 21.7 W, so plan for that heat in a sealed enclosure. The derating table above 50 °C is published, so you can size the breaker for the actual ambient inside the panel rather than oversizing by guesswork.

Frequently asked questions

Does this breaker include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) and two HQ auxiliary switches as standard.

MPN
3VA1180-4EF32-0DC0