Skip to main content
Siemens 3VA1180-4EF36-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-4EF36-0DA0 SENTRON MCCB, 80 A, 3-Pole, Line

MPN3VA1180-4EF36-0DA0

Siemens SENTRON 3VA1180-4EF36-0DA0, Molded case circuit breaker, 3-pole, 80 A, TM240 release, Line protection, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-4EF36-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1180-4EF36-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C76.8 A
Current at 60 °C75.2 A
Current at 65 °C73.6 A
Current at 70 °C72 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1180-4EF36-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1180-4EF36-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-4EF36-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1180-4EF36-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-4EF36-0DA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Rated continuous current Iu is 80 A, and the 3-pole construction handles three-phase circuits. The TM240 overcurrent release provides fixed thermal-magnetic protection — thermal for overload, magnetic for short-circuit — with no electronic adjustment. Breaking capacity runs from 121 kA at 240 V through 75.6 kA at 415 V, 52.5 kA at 440 V, down to 11.9 kA at 690 V, which covers most industrial service-entrance and feeder applications.

The 80 A continuous rating holds at ambient temperatures up to 50 °C without derating — at 55 °C it's 76.8 A, at 70 °C it's 72 A. IP40 on the front means the breaker face is protected against tools and small solids; the enclosure itself handles the rest.

Integrated undervoltage release

That means the breaker trips automatically if supply voltage drops below a threshold, which is common in safety circuits or motor control centers where you want the breaker open on loss of control power. The integrated auxiliary trip order code is 3VA9608-0BB25. No auxiliary contact version is fitted; if you need status feedback, that's a separate add-on.

Frequently asked questions

What are the key ratings for 3VA1180-4EF36-0DA0?

Rated continuous current Iu is 80 A, 3-pole, with a TM240 thermal-magnetic release. Breaking capacity is 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V. Rated insulation voltage Ui is 800 V.

Does this MCCB include an undervoltage release?

Yes, it ships with an integrated undervoltage release (UVR) as the auxiliary release design. The integrated auxiliary trip order code is 3VA9608-0BB25.

Where can I buy 3VA1180-4EF36-0DA0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for this order code.

MPN