Siemens 3VA1180-4GD46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-4GD46-0AA0 SENTRON MCCB, 80 A, 4-Pole, 121 k

MPN3VA1180-4GD46-0AA0
Active

Siemens SENTRON 3VA1180-4GD46-0AA0, molded case circuit breaker, 4-pole, 80 A, TM210 thermal-magnetic trip unit, interrupting capacity 121 kA at 240 V AC, 75.6 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-4GD46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1180-4GD46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.19.2 W
3VA1180-4GD46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1180-4GD46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-4GD46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1180-4GD46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-4GD46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Its interrupting capacity reaches 121 kA at 240 V AC and 75.6 kA at 415 V AC, giving you solid fault-clearing headroom for industrial distribution panels where high available fault currents are a concern. At 440 V the interrupting rating drops to 52.5 kA, and at 500 V or 690 V it holds at 11.9 kA — still respectable for most motor-control-center applications. The 80 A rating holds steady from 40 °C up to 50 °C; above that it derates gradually to 74 A at 70 °C, so factor in your enclosure's internal temperature rise when sizing.

Integration and fit notes

The breaker measures 130 mm high, 101.6 mm wide, and 70 mm deep — a standard footprint for SENTRON 3VA frames. Front IP40 protection means it's suited for enclosed panel mounting where dust ingress is limited.

Frequently asked questions

Where can I buy 3VA1180-4GD46-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the interrupting capacity at 240 V?

The interrupting capacity is 121 kA at 240 V AC, dropping to 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 500 V and 690 V.

Does this MCCB include an undervoltage release or ground-fault monitoring?

No — this variant has no undervoltage release and no ground-fault monitoring. It is a straight thermal-magnetic line-protection device.

MPN