Skip to main content
Siemens 3VA1180-5EF32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-5EF32-0CC0 SENTRON MCCB, 80 A, 3-Pole, 187 k

MPN3VA1180-5EF32-0CC0

Siemens SENTRON 3VA1180-5EF32-0CC0, molded case circuit breaker (MCCB), 3-pole, 80 A at 40 °C, breaking capacity 187 kA at 240 V, line protection design, undervoltage release, 2 auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1180-5EF32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11805EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1180-5EF32-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.21.7 W

Protection & Trip Unit

3VA1180-5EF32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1180-5EF32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1180-5EF32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1180-5EF32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1180-5EF32-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB delivers on the line

The Siemens SENTRON 3VA1180-5EF32-0CC0 is a molded case circuit breaker (MCCB) rated for 80 A at 40 °C, holding that rating steady through 50 °C before a mild thermal derating curve kicks in — 78 A at 55 °C, 77 A at 60 °C, 75 A at 65 °C, and 74 A at 70 °C. That means it handles a full 80 A continuous load in most ventilated enclosures without up-sizing. Breaking capacity climbs to 187 kA at 240 V, drops to 121 kA at 415 V, then 75.6 kA at 440 V, and still holds 17 kA at 500 V and 690 V. For a panel fed from a transformer with high available fault current, this breaker clears without upstream coordination headaches. Designed for line protection. Rated insulation voltage is 800 V.

Panel fit and auxiliaries

The 3-pole frame measures 76.2 mm wide, 130 mm tall, and 70 mm deep — a compact footprint that fits standard MCCB mounting patterns in Siemens SENTRON distribution boards or third-party enclosures. Factory-fitted with an undervoltage release (UVR) and two auxiliary switches (HQ design). The UVR trips the breaker if control voltage drops, a common requirement for safety circuits and motor feeder disconnects. Power loss is 21.7 W maximum at rated load — factor that into enclosure thermal calculations if the panel runs multiple breakers at full current.

Frequently asked questions

How does the 3VA1180-5EF32-0CC0 compare to the 3VA1110-5ED36-0AC0?

The 3VA1180-5EF32-0CC0 is a higher-current frame (80 A vs the 3VA1110-5ED36-0AC0's lower rating) with the same 3-pole form factor and SENTRON line protection design. The 3VA1110-5ED36-0AC0 is a functional second-source for lower-current applications, but the 80 A frame and breaking capacity differ — verify panel coordination before substituting.

Does the 3VA1180-5EF32-0CC0 include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) and two auxiliary switches (HQ design) factory-installed.

MPN
3VA1180-5EF32-0CC0