Skip to main content
Siemens 3VA1180-6ED36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-6ED36-0AA0 SENTRON MCCB, 80 A, 3-Pole

MPN3VA1180-6ED36-0AA0
Active

Siemens SENTRON 3VA molded case circuit breaker, order code 3VA1180-6ED36-0AA0, 3-pole, 80 A at 40 °C, TM210 release, 220 kA breaking capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1180-6ED36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1180-6ED36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.19.2 W

Protection & Trip Unit

3VA1180-6ED36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1180-6ED36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1180-6ED36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1180-6ED36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1180-6ED36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA — line protection MCCB, 80 A frame

The Siemens 3VA1180-6ED36-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection in distribution panels and industrial switchboards. It carries a continuous current rating of 80 A at 40 °C through 50 °C, derating to 74 A at 70 °C — so the 80 A frame holds its full rating across typical panel ambient temperatures, only dropping above 55 °C. Breaking capacity reaches 220 kA at 240 V and 154 kA at 415 V, which covers high-fault utility feeds and transformer secondaries without cascading upstream. At 500 V and 690 V the rating settles at 17 kA — still adequate for most motor-control-center bus faults. The overcurrent release is a fixed thermal-magnetic TM210 — no interchangeable trip units, so the 80 A rating is hard-set at the factory. Rated insulation voltage is 800 V, and the front face carries IP40 protection, meaning it's suitable for dry indoor panel mounting but not washdown zones.

Panel fit and dimensions

The 3VA1180-6ED36-0AA0 measures 130 mm high, 76.2 mm wide, and 70 mm deep — a 3-pole MCCB that fits standard 3-inch-wide panel cutouts. Depth is shallow enough for compact gland-plate layouts.

Frequently asked questions

Where can I buy 3VA1180-6ED36-0AA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is the breaking capacity of 3VA1180-6ED36-0AA0 at 240 V?

220 kA at 240 V, which covers high-fault utility feeds and transformer secondaries without cascading upstream.

MPN
3VA1180-6ED36-0AA0