Skip to main content
Siemens 3VA1180-6EF32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-6EF32-0AD0 SENTRON MCCB, 80A, 220kA at 240V

MPN3VA1180-6EF32-0AD0

Siemens SENTRON 3VA1180-6EF32-0AD0, 3-pole molded case circuit breaker, 80 A at 40 °C, 220 kA breaking capacity at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-6EF32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11806EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1180-6EF32-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.19.2 W
3VA1180-6EF32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1180-6EF32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-6EF32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1180-6EF32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-6EF32-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for high-fault panel protection

The Siemens 3VA1180-6EF32-0AD0 is a 3-pole SENTRON molded case circuit breaker rated for 80 A at 40 °C, with a breaking capacity of 220 kA at 240 V AC — enough to handle high-fault-current utility feeds or transformer secondaries without cascading upstream. The TM240 thermal-magnetic release provides fixed overload and short-circuit protection, no undervoltage release or ground-fault module on this variant.

Breaking capacity drops as voltage rises: 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 500 V and 690 V (–). The 80 A rating holds steady from 40 °C to 50 °C, then derates to 74 A at 70 °C (–). The 70 mm depth and 76.2 mm width fit standard SENTRON 3VA panel footprints; the 130 mm height matches the mounting centres of the 3VA family. Maximum power loss is 19.2 W.

Frequently asked questions

What is the breaking capacity of the 3VA1180-6EF32-0AD0 at 240 V?

220 kA at 240 V.

Where can I buy the 3VA1180-6EF32-0AD0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
3VA1180-6EF32-0AD0