Skip to main content
Siemens 3VA1180-6EF32-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-6EF32-0AE0 SENTRON MCCB, 80 A, 220 kA at 240

MPN3VA1180-6EF32-0AE0

Siemens SENTRON 3VA1180-6EF32-0AE0, molded case circuit breaker, 3-pole, 80 A, TM240 overcurrent release, 220 kA at 240 V, 4 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-6EF32-0AE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1180-6EF32-0AE0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C76.8 A
Current at 60 °C75.2 A
Current at 65 °C73.6 A
Current at 70 °C72 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 690 V17 kA
3VA1180-6EF32-0AE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1180-6EF32-0AE0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-6EF32-0AE0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA1180-6EF32-0AE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-6EF32-0AE0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1180-6EF32-0AE0 is a 3-pole SENTRON molded case circuit breaker rated for 80 A continuous current at 40 °C, with a TM240 thermal-magnetic overcurrent release. Its interrupting capacity hits 220 kA at 240 V, 154 kA at 415 V, and 121 kA at 440 V — numbers that tell you this breaker clears high-fault energy without cascading upstream, which matters when the line feeds a motor control center or a secondary distribution panel where available fault current is high. The thermal curve holds 80 A flat through 50 °C, then derates to 76.8 A at 55 °C and 72 A at 70 °C.

Mounts on a DIN rail or direct panel surface — the 76.2 mm width and 70 mm depth fit a standard 3-pole MCCB footprint, so it drops into existing SENTRON or 3VA-series cutouts without re-drilling the gland plate. Comes with 4 auxiliary switches HQ (high-quantity) built in, which gives you status feedback for PLC inputs or alarm annunciation without adding a separate aux block.

Frequently asked questions

Does 3VA1180-6EF32-0AE0 include auxiliary contacts?

Yes, it ships with 4 auxiliary switches HQ (high-quantity) factory-installed.

MPN
3VA1180-6EF32-0AE0